Related Experiment Videos
Accuracy of elastomeric impressions disinfected by immersion
G H Johnson1, D G Drennon, G L Powell
1Department of Restorative Dentistry, University of Washington, Seattle 98195.
Journal of the American Dental Association (1939)
|April 1, 1988
Abstract:
This study evaluates the accuracy and surface quality of stone dies made from impressions that had been placed in disinfectants. Results indicated that selection of the type of impression material is more important than selection of the disinfectant. Addition silicone and polysulfide impressions were disinfected without a loss in accuracy, whereas polyether impressions were adversely affected. The surface quality of dies was acceptable with disinfection and one disinfectant contributed to an improvement in surface quality compared with the control.