Related Experiment Video
Updated: Jan 21, 2026

Assessment of Dopaminergic Homeostasis in Mice by Use of High-performance Liquid Chromatography Analysis and Synaptosomal Dopamine Uptake
Published on: September 21, 2017
[Influence of the Each Correction Method for the Specific Binding Ratio and Standardized Uptake Value in the Dopamine
Akihiro Shiokawa1, Masahisa Onoguchi2, Takayuki Shibutani2
1Department of Radiological Technology, School of Health Sciences, College of Medical Pharmaceutical and Health Sciences, Kanazawa University (Current address: Department of Radiology, Saku Central Hospital Advanced Care Center).
Abstract:
This study was to reveal the characteristics for each correction effect of specific binding ratio (SBR) and standardized uptake value (SUV) in the dopamine transporter (DAT) single photon emission computed tomography (SPECT). We created the 123I solution of five radioactive concentrations, which was filled with two types of striatum phantom such as separated or integrated caudate and putamen. We created 10 striatum accumulation models by combining the 123I solution. Images were reconstructed using ordered subset expectation maximization (OSEM) incorporating attenuation correction (AC), scatter correction (SC) or resolution recovery (RR) for the collected data of 10 striatum accumulation models and 66 patients. Correction combinations were AC, ACSC, ACRR and ACSCRR. The SBR, SUVmean and SUVmax were evaluated correlation and relative error between SBR, SUVmean and SUVmax by each correction method. The SBR and SUV had a significant positive correlation with all correction methods. The minimum values of relative error for SBR, SUVmean and SUVmax were 39.7% with ACSCRR, 18.4% with AC and 16.5% with ACSC, respectively. In addition, the ACSC of SBR and SUVmean was almost same value. The SBR showed significantly higher values by incorporating SC, while the SUV was significantly higher values by incorporating RR. It was suggested that SUV could be used for the quantitative index of DAT SPECT. Furthermore, we demonstrated the characteristic among each correction for SBR and SUV.
More Related Videos
06:28A Simple Flow Cytometric Method to Measure Glucose Uptake and Glucose Transporter Expression for Monocyte Subpopulations in Whole Blood
Published on: August 12, 2016
09:49A Whole Body Dosimetry Protocol for Peptide-Receptor Radionuclide Therapy PRRT: 2D Planar Image and Hybrid 2D+3D SPECT/CT Image Methods
Published on: April 24, 2020
Related Concept Videos
Electron Transport Chains
The ETC is comprised of...
Gas Exchange and Transport
The Equilibrium Binding Constant and Binding Strength
Facilitated Transport
Regulated mRNA Transport
Distance Corrections