Related Experiment Video
Updated: Jan 21, 2026

Implementation of a Nonlinear Microscope Based on Stimulated Raman Scattering
Published on: July 6, 2019
Implementation of a Nonlinear Microscope Based on Stimulated Raman Scattering
Rajeev Ranjan1, Maurizio Indolfi1, Maria Antonietta Ferrara1
1National Research Council, Institute for Microelectronics and Microsystems, Naples Unit, Italy.
Abstract:
Stimulated Raman scattering (SRS) microscopy uses near-infrared excitation light; therefore, it shares many multi-photon microscopic imaging properties. SRS imaging modality can be obtained using commercial laser-scanning microscopes by equipping with a non-descanned forward detector with proper bandpass filters and lock-in amplifier (LIA) detection scheme. A schematic layout of a typical SRS microscope includes the following: two pulsed laser beams, (i.e., the pump and probe directed in a scanning microscope), which must be overlapped in both space and time at the image plane, then focused by a microscope objective into the sample through two scanning mirrors (SMs), which raster the focal spot across an x-y plane. After interaction with the sample, transmitted output pulses are collected by an upper objective and measured by a forward detection system inserted in an inverted microscope. Pump pulses are removed by a stack of optical filters, whereas the probe pulses that are the result of the SRS process occurring in the focal volume of the specimen are measured by a photodiode (PD). The readout of the PD is demodulated by the LIA to extract the modulation depth. A two-dimensional (2D) image is obtained by synchronizing the forward detection unit with the microscope scanning unit. In this paper, the implementation of an SRS microscope is described and successfully demonstrated, as well as the reporting of label-free images of polystyrene beads with diameters of 3 µm. It is worth noting that SRS microscopes are not commercially available, so in order to take advantage of these characteristics, the homemade construction is the only option. Since SRS microscopy is becoming popular in many fields, it is believed that this careful description of the SRS microscope implementation can be very useful for the scientific community.
Related Concept Videos
Nonlinear Pharmacokinetics: Causes of Nonlinearity
Nonlinear drug absorption can occur when the process is rate-limited by solubility, carrier-mediated transport systems, or saturation of the presystemic gut wall or hepatic metabolism. For instance, high doses of riboflavin...
Nonlinear Pharmacokinetics: Overview
Nonlinearity can arise due to the saturation of plasma protein-binding or...
Nursing Implementation
The five steps to implementing effective nursing care include reassessing the patient, reviewing and revising the existing nursing care plan, organizing the resources and care delivery, anticipating and preventing complications, and implementing nursing interventions.
Nonlinear Pharmacokinetics: Michaelis-Menten Equation
Vmax represents the maximum achievable process rate, while KM, known as the Michaelis constant, signifies the drug concentration at which the process rate reaches half its maximum. This relationship between Vmax, KM, and Cp gives rise to three distinct...
Nonlinear Pharmacokinetics: Role of Transporters
Polymorphisms occurring in drug transporters can alter...
Scatter Plot

