Published on: April 29, 2014
Developing an All-Digital Workflow for Dental Skills Assessment: Part I, Visual Inspection Exhibits Low Precision and
Thomas J Greany1, Ala Yassin2, K Chase Lewis2
1Thomas J. Greany, DDS, is Director of Academic Technology Initiatives and Assistant Clinical Professor, Department of Restorative Dentistry, University of Colorado School of Dental Medicine, as well as Assistant Professor, Modern Human Anatomy Program, Department of Cellular and Developmental Biology, University of Colorado School of Medicine; Ala Yassin, DDS, is an MS student, Graduate Periodontics Department, University of Colorado School of Dental Medicine; and K. Chase Lewis, MS, is a DDS student, University of Colorado School of Dental Medicine. thomas.greany@cuanschutz.edu.
Visual inspection of dental student waxups is imprecise and inaccurate. Digital assessment offers a superior alternative for consistent and valid student evaluation.
Area of Science:
- Dental Education
- Biomedical Engineering
- Restorative Dentistry
Background:
- Faculty visual inspection (VI) of dental student waxups is often subjective and inconsistent.
- Traditional grading rubrics lack precision in assessing dental morphology.
- There is a need for more objective and accurate assessment methods in dental education.
Purpose of the Study:
- To test the hypothesis that visual inspection (VI) is imprecise and inaccurate.
- To explore the development of a superior digital assessment alternative for dental waxups.
- To evaluate the precision and accuracy of both visual and digital assessment methods.
Main Methods:
- Six examiners performed visual inspection (VI) on 81 dental student waxups using a 20-item rubric.
- 67 waxups were scanned and analyzed using 3D surface comparison software.
- Examiner precision and accuracy were evaluated using digital inspection and statistical tests.
Main Results:
- Visual inspection (VI) showed low inter-examiner precision (ICC 0.332) and accuracy.
- Intra-examiner precision was also low for three examiners, indicated by statistically different mean grades.
- Independent digital evaluation by two examiners demonstrated high inter-examiner precision (ICC 0.866) and optimal accuracy.
Conclusions:
- Visual inspection (VI) of dental waxups is measurably imprecise and inaccurate.
- Digital assessment techniques offer improved visualization and more consistent, valid student evaluation.
- Digital methods facilitate optimal self-evaluation and self-correction for dental students.
Related Concept Videos
Uncertainty in Measurement: Accuracy and Precision
Accuracy and Precision
Assessment of the Cardiovascular System II: Inspection
Head and Neck
Assessment of the Abdomen I: Inspection and Auscultation
The abdominal examination is a cornerstone of clinical medicine, serving as a critical tool in diagnosing various gastrointestinal (GI) diseases. It involves a systematic approach that includes inspection and auscultation, each with distinct yet complementary roles in assessing the abdomen. This article will delve into these two primary methods healthcare professionals use to examine the abdomen.
Inspection of the Abdomen
The first step in any abdominal examination is inspection....
Physical Assessment of the Respiratory Tract II: Inspection
Chest Configuration
The chest configuration...
Nursing Assessment of the Genitourinary System II: Inspection and Palpation