Related Experiment Video
Updated: Jan 21, 2026

Adapting Human Videofluoroscopic Swallow Study Methods to Detect and Characterize Dysphagia in Murine Disease Models
Published on: March 1, 2015
Standardization of Radiologic Procedures for Pediatric Videofluoroscopic Swallow Studies: A Service-based Quality
Benjamin Thompson1, Jennifer P Lundine2,3, Lauren Madhoun3
1Department of Radiology, Nationwide Children's Hospital, Columbus, Ohio.
Introduction:
The videofluoroscopic swallow study (VFSS) remains the primary method to evaluate swallowing function in infants and children. However, limited standards exist to guide the image acquisition during pediatric VFSSs, leading to inadequate images, variable assessment quality, and potential for suboptimal diagnostic accuracy. The goal of this quality improvement project was to standardize the radiological procedure for radiologists at our institution.
Methods:
A multidisciplinary team of project leaders established 3 imaging standards to target (magnification, the field of view, and pulse repetition rate), based on the best available evidence. The team used the Institute for Healthcare Improvement's Model for Improvement to guide the project, identified key drivers, and implemented specific interventions. Project leaders observed a total of 170 VFSS examinations, performed by radiology faculty, fellows, and residents over 24 months. The primary outcome for this project was physician compliance with 3 established imaging standards: field of view, magnification, and pulse repetition rate. Project leaders collected data without the radiologists' knowledge, and also recorded average radiation exposure as a balancing measure during this process.
Results:
At baseline, compliance with all 3 criteria was 20%. Following interventions designed to improve radiologist performance with the 3 identified standards, the compliance rate reached 100% for the last 50 recorded VFSSs. During this same time, there was no meaningful increase in average radiation exposure compared with the 6 months before the implementation of this project.
Conclusions:
Compliance with standardized image acquisition of VFSSs can be accomplished using a systematic quality improvement protocol targeting simple, inexpensive interventions.
Related Concept Videos
Handwashing II: Pre-procedure and Initial Procedure Steps
The hand washing procedure itself includes the following steps. First, cover cuts, if any, on hands with a waterproof dressing. Cuts and abrasions can become contaminated with bacteria hindering the ability to clean the area thoroughly. In addition, repeated hand washing can worsen an injury. The nails must be short and clean, without nail...
Initiation of Translation
First, the initiator tRNA must be selected from the pool of elongator tRNAs by eukaryotic initiation factor 2 (eIF2). The initiator tRNA (Met-tRNAi) has conserved sequence elements including modified bases at...
Initiation of Translation
Upper GI Series: Barium Swallow
Purpose and Procedure
Patients undergoing this procedure ingest a liquid containing barium sulfate with a chalky...
Blind Procedures
Radiological Investigation I: X-ray and CT