Experimental designs for optimizing the purification of immunoglobulin G by mixed-mode chromatography
P L R de Sousa1, P A S Tavares1, E M T S Teixeira1
1Universidade Federal do Ceará, Centro de Tecnologia, Departamento de Engenharia Química - Grupo de Pesquisa em Separações por Adsorção - GPSA, Campus do Pici, Bl. 709, CEP: 60455-760 Fortaleza, CE, Brazil.
Abstract:
The main aim of this study was to define the optimal adsorption and elution conditions for the purification of human immunoglobulin G (IgG) by mixed-mode chromatography using the multimodal resin Capto MMC. To this end, Central Composite Experimental Design (ED) was performed for both the adsorption and desorption stages. In the first case, the conditions were systematically studied in batch mode while in the latter case, these were performed in column. For both studies, the experimental design was conducted using high-purity human IgG samples. Buffer pH and concentration as well as the salt concentration were the parameters under study in the ED. Adsorption kinetics and equilibrium experiments were performed under the best conditions defined in the ED (phosphate buffer 60 mmol/L, pH 6.75, no salt). The equilibrium experimental data were fit to the Langmuir equation, with maximum uptake qmax equal to 549.2 mg/g. The qmax value found for IgG in Capto MMC was quite high as compared to other chromatographic techniques that employ single modes of interaction. Regarding elution, the best conditions were obtained with acetate buffer (56.40 mmol/L), pH 5.2 and 0.2 mol/L NaCl. An ultimate recovery of 46.96% for high-purity IgG was achieved. Thus, the effectiveness of Capto MMC for IgG adsorption and recovery could be confirmed. Moreover, electrophoretic runs in the human serum indicated that although co-elution of HSA and IgG proteins occurs, substantial HSA removal and a high IgG recovery were achieved in the elution step.
Related Concept Videos
Design Example: Vintage Mixing Console
The specifications for the pre-amplifier were clear. It needed to amplify the audio signal by a factor of 10, have an input impedance above 10...
Experimental Designs
Bioequivalence Experimental Study Designs: Completely Randomized and Randomized Block Designs
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...
Group Design
Bioequivalence Experimental Study Designs: Repeated Measures, Cross-Over, Carry-Over, and Latin Square Designs