Related Experiment Video
Updated: Jan 21, 2026

Assessment of Boron Doped Diamond Electrode Quality and Application to In Situ Modification of Local pH by Water Electrolysis
Published on: January 6, 2016
Curcumin nanoparticle doped starch thin film as a green colorimetric sensor for detection of boron
Chanita Boonkanon1, Kharittha Phatthanawiwat1, Worawit Wongniramaikul1
1Integrated Science and Technology Research Center, Faculty of Technology and Environment, Prince of Songkla University, Phuket Campus, Kathu, Phuket 83120, Thailand.
Abstract:
A tapioca starch film doped with curcumin nanoparticles was successfully fabricated and applied as a novel green colorimetric sensor for detection of boron in wastewater. Curcumin nanoparticles (curn, 30-90 nm) extracted from turmeric powder were used as a green probe, while tapioca starch was used as a natural support substrate. A yellow thin film (51 μm thick) fabricated on a used plastic spoon turned red-brown after immersion in boron solution (pH 9) for 15 min with excellent selectivity. The film costs only 0.0007 USD, while the cost of the sensor (curn-film on new plastic spoon) was 0.004 USD. After use the film could be completely washed from the plastic, it being biodegradable, while the used plastic spoon could be re-used to fabricate a new sensor at least 10 times. The good 1.52%RSD precision was obtained across three lots fabricated. When the curn-film was used in conjunction with digital image colorimetry (DIC), a simple and rapid quantification of boron was achieved. The green color layer in reflected light image of the red-brown product (IG) provided the highest sensitivity (64 ± 1 a.u. L mg-1) and the lowest detection limit of 0.052 ± 0.001 mg L-1. The intra-day testing (9 films) had 2.41 to 4.34%RSD, while the inter-day testing had 2.29 to 5.66%RSD (15 films, 5 days). Accuracy in terms of relative error for control samples (0.40 mg L-1) was +3.63%. Wastewater samples from Para-rubber wood processing plant were quantified by curn-film and DIC, giving 4248 ± 391 mg L-1 boron concentration with no significant difference to ICP determination at 95% confidence level. The sensors after storage in a desiccator for a year gave readings changed by only +3.5% and -2.1% relative to freshly prepared sensors.
More Related Videos
Related Concept Videos
Green Algae
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...

