Related Experiment Video
Updated: Jan 21, 2026

Proton Therapy Delivery and Its Clinical Application in Select Solid Tumor Malignancies
Published on: February 6, 2019
Range and dose verification in proton therapy using proton-induced positron emitters and recurrent neural networks
Chuang Liu1, Zhongxing Li1, Wenbin Hu2
1Department of Medical Physics, Wuhan University, Wuhan, 430072, People's Republic of China.
Abstract:
Online proton range/dose verification based on measurements of proton-induced positron emitters is a promising strategy for quality assurance in proton therapy. Because of the nonlinear correlation between the dose distribution and the activity distribution of positron emitters, we aim to establish their relationship using recurrent neural network models (LSTM, BiLSTM, GRU, BiGRU and Seq2seq). Simulations were carried out with a spot-scanning proton system using Geant4-10.3 toolkit and a CT-based patient phantom. The 1D distributions of positron emitters and radiation dose were obtained. Training data were modeled for different beam energy, irradiation positions and counting statistics. The prediction accuracy of range and dose were quantitatively studied. The impact of including anatomical information (HU values in CT images) on the prediction performance was investigated. The BiGRU demonstrates the most stable and accurate performance with good capability of generalization, especially with the inclusion of anatomical information. When the signal-to-noise ratio (SNR) of the 1D activity profiles is about 3, the range accuracy can be within 0.5 mm and the dose accuracy close to the peak region is <5% (relative uncertainty between prediction and raw input for all datasets). The feasibility of proton range and dose verification using the RNN-based framework was demonstrated. The RNN-based framework promises to provide a reliable and effective way for online monitoring, quality assurance and ultimately allows for adaptive proton therapy.
More Related Videos
07:38Functional Characterization of Na+/H+ Exchangers of Intracellular Compartments Using Proton-killing Selection to Express Them at the Plasma Membrane
Published on: March 30, 2015
05:51Isotopic Effect in Double Proton Transfer Process of Porphycene Investigated by Enhanced QM/MM Method
Published on: July 19, 2019
Related Concept Videos
Proton (¹H) NMR: Chemical Shift
Absorption signals of all the protium nuclei...
¹H NMR of Labile Protons: Temporal Resolution
The –OH proton in alcohols typically appears in the range of δ 2 to 5 ppm but can vary depending on the specific...
¹H NMR of Labile Protons: Deuterium (²H) Substitution
¹H NMR Chemical Shift Equivalence: Homotopic and Heterotopic Protons
¹H NMR Chemical Shift Equivalence: Enantiotopic and Diastereotopic Protons
In chiral compounds such as 2-butanol, replacing the methylene hydrogens at C3 produces a pair of...
Acid Suppressive Drugs for Peptic Ulcer Disease: Proton Pump Inhibitors
Gastric acid, a potent cocktail of hydrogen and chloride ions, is produced in specialized parietal cells within the...