Related Experiment Video
Updated: Jan 21, 2026

Quantification of Oculomotor Responses and Accommodation Through Instrumentation and Analysis Toolboxes
Published on: March 3, 2023
Effects of Optical Correction Method on the Magnitude and Variability of Accommodative Response: A Test-retest Study
Raimundo Jiménez1, Beatriz Redondo1, Leon N Davies2
1Department of Optics, University of Granada, Granada, Spain.
Significance:
The present study addresses the accommodative response and its dependence on the type of optical correction used. The results are discussed relative to their possible implications for myopia progression and visual fatigue.
Purpose:
The accommodative response has been investigated owing to its possible relationship with the onset and progression of myopia and visual fatigue. This study explored the influence of wearing soft contact lenses in comparison with spectacles in terms of magnitude and variability of accommodation. In addition, we analyzed the intersession and intermethod repeatability.
Methods:
Dynamic accommodative response was recorded during 30-second epochs, at five different distances (50, 40, 33, 25, and 20 cm), in 21 individuals (mean refractive error ± SD, -0.79 ± 1.39 D) while wearing either soft contact lenses or spectacles on two different days. To assess repeatability, a second identical intervention was conducted.
Results:
Higher lags of accommodation were obtained with the use of soft contact lenses in comparison with the spectacle condition (P = .04, partial η [ηp] = 0.204), and similarly, a higher variability of accommodation at near distances was found during the soft contact lens measurement (P < .001, ηp = 0.647). There was a strong intersession repeatability at all the distances tested for both optical correction methods.
Conclusions:
The higher accommodative lag and fluctuations found while wearing soft contact lenses in comparison with spectacles may help to understand the mechanisms underlying myopia progression and asthenopia. These findings may be also considered when testing the accommodative response in research settings. Our test-retest design confirmed that there is a very good intersession repeatability for all the distances in both optical correction methods.
Related Concept Videos
Orders of Magnitude
The order of magnitude is simply a way of rounding numbers consistently to the nearest power of 10. This makes doing rough mental math...
Distance Corrections
Power Factor Correction
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Variables Affecting Phosphorescence and Fluorescence
Variability: Analysis
The range is a simple measure of variability, indicating the difference between the highest and...

