Related Experiment Video
Updated: Jan 21, 2026

Development of a Neonatal Piglet Acute Lung Injury Model Recreating the Early Environment of Preterm Infant Lungs
Published on: October 31, 2025
Targeting Arterial Oxygen Saturation by Closed-Loop Control of Inspired Oxygen in Preterm Infants
Nelson Claure1, Eduardo Bancalari1
1Division of Neonatology, Department of Pediatrics, University of Miami Miller School of Medicine, PO Box 016960 R-131, Miami, FL 33101, USA.
Insights
Premature infants often experience harmful oxygen level fluctuations. Closed-loop oxygen systems aim to improve oxygen targeting (SpO2) and reduce risks to infant organs.
Area of Science:
- Neonatal medicine
- Respiratory physiology
- Medical technology
Background:
- Premature infants are susceptible to organ damage from abnormal blood oxygen levels (hyperoxemia and hypoxemia).
- Respiratory instability and resource limitations complicate maintaining optimal oxygen saturation (SpO2) in these infants.
- Extreme SpO2 levels pose significant risks to the developing eyes, lungs, and central nervous system.
Purpose of the Study:
- To review clinical evidence on the efficacy of closed-loop systems for oxygen control in extremely premature infants.
- To assess the impact of these systems on SpO2 targeting and patient safety.
- To evaluate the potential of advanced technology in managing respiratory support for vulnerable neonates.
Main Methods:
- Systematic review of clinical studies.
- Analysis of data from trials evaluating closed-loop oxygen control systems.
- Focus on studies involving extremely premature infants.
Main Results:
- Closed-loop systems demonstrate potential in improving SpO2 targeting accuracy.
- Evidence suggests these systems may reduce exposure to extreme oxygen levels.
- Further research is needed to fully establish long-term benefits and safety profiles.
Conclusions:
- Closed-loop oxygen control systems offer a promising approach to managing SpO2 in premature infants.
- These systems may mitigate risks associated with hyperoxemia and hypoxemia.
- Continued evaluation is crucial for optimizing their use in neonatal intensive care.
Abstract:
Exposure to hyperoxemia from excessive oxygen supplementation and episodes of intermittent hypoxemia have been associated with damage to the eye, lung, and central nervous system in premature infants. The inherent respiratory instability of the premature infant combined with limited staffing or equipment resources often affect SpO2 targeting and increase exposure to extreme SpO2 levels. Multiple systems for closed loop control of inspired oxygen have been developed to improve SpO2 targeting. This article reviews the evidence provided by clinical studies evaluating the efficacy of these systems in extreme premature infants.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Open and closed-loop control systems
An open-loop control system operates without feedback from the output. It consists of two primary elements: the controller and the controlled process. The controller receives an input signal...
Oxygen Delivering System II: Venturi Mask and Transtracheal Oxygen
Venturi Mask
The Venturi mask, named after the Venturi effect, is designed to deliver precise oxygen concentrations. It consists of a large tube with an oxygen inlet that narrows down, causing a pressure drop that pulls air in through adjustable side ports. The mask is a lightweight,...
Oxygen Transport in the Blood
Oxygenic Photosynthesis
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...