Related Experiment Video
Updated: Jan 21, 2026

Application of Deep Learning-Based Medical Image Segmentation via Orbital Computed Tomography
Published on: November 30, 2022
Deep-learning-assisted automatic digitization of applicators in 3D CT image-based high-dose-rate brachytherapy of
Hyunuk Jung1, Yesenia Gonzalez1, Chenyang Shen1
1Innovation Technology of Radiotherapy Computation and Hardware (iTORCH) Lab, University of Texas Southwestern Medical Center, Dallas, TX; Medical Artificial Intelligence and Automation (MAIA) Lab, University of Texas Southwestern Medical Center, Dallas, TX; Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX.
Purpose:
Applicator digitization is one of the most critical steps in 3D high-dose-rate brachytherapy (HDRBT) treatment planning. Motivated by recent advances in deep-learning, we propose a deep-learning-assisted applicator digitization method for 3D CT image-based HDRBT. This study demonstrates its feasibility and potential in gynecological cancer HDRBT.
Methods And Materials:
Our method consisted of two steps. The first step used a U-net to segment applicator regions. We trained the U-net using two-dimensional CT images with a tandem-and-ovoid (T&O) applicator and corresponding applicator mask images. The second step applied a spectral clustering method and a polynomial curve fitting method to extract applicator central paths. We evaluated the accuracy, efficiency, and robustness of our method in different scenarios including other T&O cases that were not used in training, a T&O case scanned with cone-beam CT, and Y-tandem and cylinder-applicator cases.
Results:
In test cases with a T&O applicator, average 3D Dice similarity coefficient between automatic and manual segmented applicator regions was 0.93. Average distance between tip positions and average Hausdorff distance between applicator channels determined by our method and manually were 0.64 mm and 0.68 mm, respectively. Although trained only using CT images of T&O cases, our tool can also digitize Y-tandem, cylinder applicator, and T&O applicator scanned in cone-beam CT with error of tip position and Hausdorff distance <1 mm. Computation time was ∼15 s per case.
Conclusions:
We have developed a deep-learning-assisted applicator digitization tool for 3D CT image-based HDRBT of gynecological cancer. The achieved accuracy, efficiency, and robustness made our tool clinically attractive.
Related Concept Videos
Drug Dosing in Renal Diseases: Dose Adjustments Based on Drug Clearance and Elimination Rate Constant
Application of Rates of Change
Drug Dosing in Renal Diseases: Estimation of Glomerular Filtration Rate Based on Serum Creatinine Concentration
Imaging Studies I: CT and MRI
Description of the Procedures
Computed Tomography (CT) scan:
Computed Tomography (CT) scans use X-ray technology to generate detailed images of bones, organs, and tissues. During the scan, the patient lies on a moving table...
Imaging Studies for Cardiovascular System V: CT
Automatic Processing and Automatic Social Behavior