Odysight: A Mobile Medical Application Designed for Remote Monitoring-A Prospective Study Comparison with Standard
Julie Brucker1, Vinona Bhatia2, José-Alain Sahel3,4
1Tilak Healthcare, 74 Rue de Faubourg Saint Antoine, 75012, Paris, France.
Introduction:
The purpose of this study (Tilak Study No: TIL-001) was to evaluate the medical modules on the mobile medical application OdySight and compare them to the gold standard tests for visual acuity, contrast sensitivity, and Amsler Grid.
Methods:
A total of 120 eyes were evaluated in an open-label, single-arm, prospective, single-site study during which participants performed monocular, gold standard tests for measuring visual acuity (Sloan Early Treatment Diabetic Retinopathy Study [ETDRS] letter chart at 40 cm testing distance and ETDRS letter chart at 4 m testing distance [40-cm and 4-m ETDRS, respectively), contrast sensitivity (Pelli-Robson contrast sensitivity chart [Pelli-Robson test]), and metamorphopsia/scotoma (Amsler Grid) followed by the respective modules on OdySight (also monocular). During this study, both the distance between the device and the patient's eye and room illumination were controlled by the examiner.
Results:
A Bland-Altman analysis demonstrated that there was no disagreement between the results of the OdySight visual acuity module and both the 40-cm Sloan ETDRS and 4-m ETDRS tests, with a very low level of bias (0.53 and - 1.53 letters, respectively). The same analysis of contrast sensitivity showed a broader disagreement between the results of the OdySight module and those of the Pelli-Robson test. A McNemar test indicated that there was no significant difference between results obtained by the OdySight Amsler Grid module and those obtained by the paper version for the detection of metamorphopsia and scotoma (p = 1.0 for both).
Conclusion:
The results from the TIL-001 study demonstrate good agreement, overall, between the measurements taken by the near visual acuity module and the Amsler grid module of OdySight as compared to currently used gold standards. The contrast sensitivity module of OdySight will require additional investigation. OdySight could be used for remote monitoring of vision between clinic visits and potentially assist in follow-up planning.
Funding:
Tilak Healthcare funded the study and the Rapid Service Fees.
Trial Registration:
ClinicalTrials.gov identifier: NCT03457441.
More Related Videos
Related Concept Videos
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
Testing a Claim about Standard Deviation
The hypothesis testing for the claim of population standard deviation (or variance) requires the data and samples to be random and unbiased. The population distribution also must be normal. There is no specific requirement on the sample size as the estimation is based on the chi-square distribution.
As a first step, the hypothesis (null and alternative) concerning the claim about...
Design Example: Application of Archimedes' Principle
The volume of seawater displaced by the block is determined by first calculating the block's weight. This is done by multiplying the...
Myocarditis II: Clinical Features and Diagnostic Tests
Atherosclerosis II: Clinical Manifestations and Diagnostic Tests
Pericarditis II: Clinical Features and Diagnostic Tests