Related Experiment Video
Updated: Jan 21, 2026

Application of Hemostatic Devices in Laparoscopic Hepatectomy
Published on: April 19, 2022
Application techniques of a novel hemostat in cardiac operations: HEMOBLAST
Brian A Bruckner1, Uy Ngo1, Mahesh Ramchandani1
1Houston Methodist Hospital, Methodist DeBakey Heart & Vascular Center, Houston, Texas.
Background:
Postoperative bleeding complications are associated with less favorable outcomes in cardiac surgery and contribute to excessive overall healthcare costs. HEMOBLAST (Biom'up, Lyon, France) (HB) is a novel ready-to-use hemostatic powder that consists of porcine collagen, bovine chondroitin sulfate, and human pooled plasma thrombin that may help reduce surgical bleeding.
Aims:
The aim of this study was to describe the techniques of application for this new combination powder-based hemostat, HB, and demonstrate its use employing photographs of application methods during cardiac procedures.
Materials And Methods:
The initial 24 procedures in which HB was used at our institution included: left ventricular assist device (LVAD) insertions, lung transplants, heart transplants, aortic valve replacements, coronary artery bypass grafting, and mitral valve repair.
Results:
Hemostasis was achieved in all cases and there were no instances of mediastinitis, sternal infections, allergic reactions, or 30-day mortality.
Discussion:
This report describes the best methods of application of HB including use for treatment of mediastinal bleeding in a re-operative procedure in a patient on antiplatelet agents and sternal bleeding during an LVAD insertion. Proper application can facilitate excellent hemostasis using this powder.
Conclusion:
HB is a novel powder-based multiple component hemostatic agent that promotes focal or large area hemostasis. We have presented the techniques of use that are important to the successful application of HB to facilitate hemostasis.
More Related Videos
08:40TAPE: A Biodegradable Hemostatic Glue Inspired by a Ubiquitous Compound in Plants for Surgical Application
Published on: June 8, 2016
06:22Author Spotlight: Advancing Cardiovascular Research — Tailored Langendorff Perfusion Techniques for Improved Experimental Outcomes
Published on: June 14, 2024
Related Concept Videos
Operational Amplifiers
Vector Operations
A vector multiplied by a scalar value is called scalar multiplication. The result obtained is a new vector with a different magnitude. If the scalar is positive, the direction of the vector remains the same, but if it is negative, the direction of the vector is reversed. For example, the product of the mass and velocity yields the momentum.
Operant Conditioning
Reinforcement in operant conditioning can be positive or negative, both of which serve to increase the likelihood of a behavior. Positive...
Modes of Operations of BJT
Active Mode: The most common mode for amplification, the active mode features a forward-biased emitter-base junction and a reverse-biased base-collector junction. This setup enables electrons to be injected from the emitter to the base while blocking the majority carriers at the collector. The...
Second Derivatives and Laplace Operator
Consider a scalar function. The curl of its...
Basic Operations on Signals
Time Reversal mirrors a continuous-time signal about the vertical axis at t=0. This is achieved by substituting t with −t. For example, if a signal x(t) is considered, the time-reversed signal is x(−t). This operation can be graphically represented, showing the mirrored signal.