Cone Beam Intraoperative Computed Tomography-based Image Guidance for Minimally Invasive Transforaminal Interbody Fusion
Published on: August 6, 2019
Development of mobile intraoperative computed tomography imaging system and assessment of its performance in a brain
Tae-Hoon Kim1, Jong-Hyun Ryu1, KilHwan Jeong
1Medical Convergence Research Center, Wonkwang University, Iksan, Jeonbuk, South Korea.
Background:
Intraoperative computed tomography (iCT) system has been developed focusing on combining the advanced imaging techniques for the best imaging modality. However, the use of iCT system in the operating rooms is limited due to the lack of flexible mobility.
Objective:
This study aims to develop a mobile iCT imaging system and assess its imaging performance in a phantom study.
Methods:
The mobile iCT system with mecanum omni-directional wheels has three major components namely, a rotating gantry, a slip-ring and a stationary gantry. Performance of mecanum iCT system was evaluated using the indices of signal-to-noise (SNR), contrast-to noise (CNR), and spatial resolution (MTF). Anatomical landmarks on phantom images were assessed using a 5-point scale (5 = definitely seen; 4 = probably seen; 3 = equivocal; 2 = probably not seen; and 1 = definitely not seen).
Results:
The mecanum iCT system can be conveniently used for a whole-body scan under intraoperative conditions even in narrow operating rooms due to a smaller turning radius. The image quality of the mecanum iCT system was found to be acceptable for clinical applications (with SNR = 162.72, CNR = 134.29 and MTF = 694 μm). The diagnostic scores on the phantom images were 'definitely seen' value.
Conclusions:
The proposed mecanum iCT system achieved the improved flexible mobility and has potential to better serve as a useful imaging tool in the clinical intraoperative setting.
More Related Videos
05:32A High-performance Compact Photoacoustic Tomography System for In Vivo Small-animal Brain Imaging
Published on: June 21, 2017
16:01An Experimental Protocol for Assessing the Performance of New Ultrasound Probes Based on CMUT Technology in Application to Brain Imaging
Published on: September 24, 2017
Related Concept Videos
Imaging Studies III: Computed Tomography
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Imaging Studies II: Positron Emission Tomography and Scintigraphy
Fundamental Principles of PET
Assessing Body Temperature - Rectal
Follow these steps for rectal temperature assessment:
Step 1: Perform hand hygiene and don clean gloves to prevent cross-infection.
Step 2: Position the patient in a side-lying position to better visualize the rectal...
Assessing Body Temperature - Oral
Step 1:
Start by practicing proper hand hygiene to prevent the spread of microorganisms.
Step 2:
Take the thermometer out of the charging unit, switch it on, and wait for the ready sign.
Step 3:
Gently slide the probe cover until a click is heard. This simple action prevents cross-contamination and ensures the correct placement of the probe cover.
Step 4:
Instruct the patient to open their mouth and place...
Assessing Body Temperature - Axilla
Step 1: Perform hand hygiene and put on clean gloves to maintain infection control and prevent cross-contamination.
Step 2: Prepare the patient by explaining the procedure to ensure understanding and cooperation. Ensure privacy, expose the axilla, and inform the patient that minimal movement is crucial for an accurate reading.
Step 3: Adjust the patient’s clothing to expose only the axilla. It minimizes...