Guidewire-assisted vs. direct radial arterial cannulation in neonates and infants: A randomised controlled trial
Young-Eun Jang1, Eun-Hee Kim, Ji-Hyun Lee
1From the Department of Anesthesiology and Pain Medicine, Seoul National University Hospital (Y-EJ, E-HK, J-HL) and Department of Anesthesiology and Pain Medicine, Seoul National University Hospital, Seoul National University College of Medicine, Seoul, Republic of Korea (H-SK, J-TK).
Background:
Cannulation of the radial artery is challenging to perform in neonates and infants because of the small vessel size.
Objective:
To compare guidewire-assisted with direct radial artery cannulation in neonates and infants.
Design:
A randomised controlled study.
Setting:
A tertiary university hospital from 7 August 2017 to 4 July 2018.
Patients:
Ninety neonates and infants who required radial artery cannulation during general anaesthesia.
Interventions:
All patients were allocated randomly into the guidewire group (guidewire-assisted cannulation, n=45) or control group (direct cannulation, n=45). Radial artery cannulation was performed under general anaesthesia. The contralateral radial artery was used if the arterial cannulation was not successful within two attempts. After the second failure in the contralateral radial artery, the case was considered a failure.
Main Outcome Measures:
The primary outcome was the first-attempt success rate of radial artery cannulation. The secondary outcomes included the overall success rate, overall procedure time, number of attempts and use of the contralateral radial artery for radial artery cannulation.
Results:
The guidewire group showed a higher first-attempt success rate [76 vs. 56%; P = 0.046; odds ratio (OR) 2.47, 95% confidence interval (CI) of odds 1.01 to 6.08] and overall success rate (96 vs. 76%; P = 0.007; OR 6.96; 95% CI 1.44 to 33.52) than the control group. The overall procedure time was not significantly different between the guidewire group (median [IQR] 36 [28.0 to 70.5] s) and control group (98 [23.5 to 465.0] s; P = 0.400). There was no difference in the median number of attempts between the two groups (P = 0.454). However, use of the contralateral radial artery was significantly lower in the guidewire group (17.8%) than in the control group (40%; P = 0.020; OR 0.324, 95% CI 0.12 to 0.86). Kaplan-Meier analysis of the overall procedure time to successful radial artery cannulation showed that the overall success rate was significantly higher in the guidewire group than in the control group (P = 0.019).
Conclusion:
For radial artery cannulation in neonates and infants, guidewire-assisted radial artery cannulation showed superiority over the direct technique in terms of first-attempt success rate and overall success rate without delaying the procedure time.
Trial Registration:
Clinicaltrials.gov (identifier: NCT03217019).
Related Concept Videos
Radial System Protection
In a radial system with a fault downstream of the third breaker, ideally, only the third breaker will open, isolating the fault and interrupting the load connected beyond it. The second breaker has a longer delay setting,...
Clinical Trials
There are four phases in a clinical trial. A phase one...
Clinical Trials: Overview
Trial and Error and Algorithm
Assessment of radial pulse
The radial pulse, located at the wrist, is often the preferred site for assessing peripheral pulse because of its accessibility and dependability. The process of determining the radial pulse involves several steps:
Assessment of apical radial pulse
The A-R pulse assessment involves simultaneous evaluation of the apical and radial pulses. When the apical and radial pulse rates vary, this assessment helps identify a pulse deficit.
Pre-Procedural Preparation