Related Experiment Video
Updated: Jan 21, 2026

Extraction of Non-Protein Amino Acids from Cyanobacteria for Liquid Chromatography-Tandem Mass Spectrometry Analysis
Published on: December 9, 2022
Altered Platelet Fatty Acids in Dengue Cases by Gas Chromatography-Mass Spectrometry Analysis
Daisy Mariya Samadanam1, Krishna Raja Muthuraman1, Vignesh Mariappan2
1Department of Biochemistry, Jawaharlal Institute of Postgraduate Medical Education and Research (JIPMER), Puducherry, India.
Background:
The role of dengue virus in altering the functional properties of platelets remains poorly understood. Few studies have observed that changes in fatty acids are found to have an effect on platelet activation and aggregation. Also, platelet fatty acids have not been extensively studied in dengue so far. So, we aimed to study the fatty acids of platelet membranes in patients with dengue.
Methods:
Gas chromatography-mass spectrometry (GC-MS) method was used to analyze fatty acids in the lipid extracts of platelets isolated from the study participants.
Results:
GC-MS analysis of platelet lipids identified and quantified nearly 23 unique lipid molecules on platelet membrane. We observed significant alterations with some of the fatty acids in patients with dengue compared to controls. Within dengue cases, increase in unsaturated fatty acids in severe dengue was observed compared to non-severe dengue. From baseline to defervescence, no difference in fatty acids was observed in dengue platelets. This indicates that in dengue, platelet physiology remains altered even after the febrile phase.
Conclusion:
To the best of our knowledge, this is the first study characterizing the differential expression of platelet fatty acids in dengue infection. However, further studies are warranted to expound the underlying cause for thrombocytopenia and platelet dysfunction in dengue.
More Related Videos
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
11:08The Use of Gas Chromatography to Analyze Compositional Changes of Fatty Acids in Rat Liver Tissue during Pregnancy
Published on: March 13, 2014
Related Concept Videos
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Mass Spectrometry: Complex Analysis
GC–MS is a powerful hyphenated method commonly used in forensics and environmental...
Gas Chromatography: Introduction
In GC, a sample is vaporized and mixed with an inert carrier gas (the mobile phase), which transports it through a...
Mass Spectrometry: Carboxylic Acid, Ester, and Amide Fragmentation
For example, the...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II