New generation of sequential injection chromatography: Great enhancement of capabilities of separation using flow
Petr Chocholouš1, Dalibor Šatínský1, Petr Solich1
1Department of Analytical Chemistry, Charles University, Faculty of Pharmacy in Hradec Králové, Akademika Heyrovského 1203/8, 500 05, Hradec Králové, Czech Republic.
Abstract:
Since its inception, sequential injection chromatography (SIC) has evolved through several stages. Key moments including introduction of the novel technique combining sequential injection analysis and monolithic column, the first generation of commercial SIC system employing robust pump, the utilization of columns packed with fused-core particles, the on-line hyphenation of extraction and separation steps in SIC, are now followed by the second generation of commercial SIC system employing stainless steel syringe pump and parts optimized for chromatographic separation. The key developments always mean acceleration of the evolution by opening new avenues and reduction of compromises in automated analytical methods based on the flow analysis. The updates, new features, and prospects of the novel instrument are described and discussed on perspective of the method developed for extraction and separation of selected phenolic acids (gallic, protocatechuic, caffeic, p-coumaric and ferulic). The method hyphenates miniaturized on-line solid phase extraction using strong anion exchange sorbent in commercial cartridge for HPLC (20 × 1 mm) and liquid chromatography using chromatographic column (C18 50 × 4.6 mm, 5 μm particles) packed with fused-core particles in the SIC manifold. The separation in gradient mode used acetonitrile: aqueous formic acid pH 2.0 mobile phase and spectrophotometric detection at 270, 300, and 320 nm. Injected sample volumes were 200 and 500 μL. The performance of the extraction step was characterized by the recovery 94.0-107.8%, enrichment factors about 20 or 50, and the separation by peak capacities 13-34, peak symmetries 1.17-1.64, and resolutions 0.82-3.75). While using a sample volume of 200 μL, our method was characterized by the following validation parameters: LODs of 0.0075-0.03 mg L-1, LOQs of 0.025-0.10 mg L-1, calibration ranges 0.025-2.50 mg L-1 (r > 0.999), repeatability of signal at 0.50 mg L-1of RSD ≤ 1.46% (n = 6), and overall time of analysis 7.1 min. The results including pilot analysis of white and red wines demonstrated the capability of novel SIC instrument to enable fast, selective, and sensitive analysis.
More Related Videos
09:03Rapid In Vivo Assessment of Adjuvant's Cytotoxic T Lymphocytes Generation Capabilities for Vaccine Development
Published on: June 19, 2018
13:46Separation of Single-stranded DNA, Double-stranded DNA and RNA from an Environmental Viral Community Using Hydroxyapatite Chromatography
Published on: September 29, 2011
Related Concept Videos
Gas Chromatography: Sample Injection Systems
Two primary injection methods are used...
Gene Flow
Self-Evaluation: Self-Enhancement and Self-Verification
Affinity Chromatography
Chromatography: Introduction
The phase in which the compounds linger or on which the compounds adsorb is called the stationary phase, whereas the mobile phase is the solvent that carries the solutes to be analyzed. In traditional column chromatography, the mixture flows through the stationary phase, and the compounds partition between the stationary and mobile phases...
Bioavailability Enhancement: Drug Solubility Enhancement