Artesunate-luminol chemiluminescence system for the detection of hemin
Tadesse Haile Fereja1, Shimeles Addisu Kitte2, Wenyue Gao2
1State Key Laboratory of Electroanalytical Chemistry, Changchun Institute of Applied Chemistry, Chinese Academy of Sciences, 5625 Renmin Street, Changchun, Jilin, 130022, PR China; University of Chinese Academy of Sciences, Beijing, 100049, PR China; Ambo University, College of Medicine and Health Sciences, Department of Pharmacy, P.O.Box 19, Ambo, Ethiopia.
Abstract:
Fabricating simple, accurate and user-friendly diagnostic device for "point of care testing" (POCT) applications is one of the most challenging objectives in the analytical field. Hemin detection is important for drugs monitoring, diagnosis, and forensic latent bloodstain imaging. Herein is developed, luminol chemiluminescence biosensor for hemin detection using artesunate as coreactant. A possible mechanism to account for the chemiluminescence reaction is discussed. Hemin was detected using both photomultiplier tube (PMT) and smartphone as detector. The detection limit for hemin using smartphone as detector is 20 nM, enabling the visual detection of hemin in blood sample with a dilution factor of blood up to 120,000. While PMT detector is used, the system is able to detect hemin down to 0.22 nM. In addition to high sensitivity, this sensing system exhibit high selectivity. It can successfully distinguish bloodstain from other stains while applying the system for point of care testing using smart phone as detector. Moreover, the system can detect artesunate with a linear range from 0.1 nM to 1.0 μM with a limit of detection of 0.078 nM.
Related Concept Videos
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...
Precipitation Titration: Endpoint Detection Methods
In the Volhard method, a standard excess of AgNO3 is first added to the...