Related Experiment Video
Updated: Jan 21, 2026

RNA-seq Analysis of Transcriptomes in Thrombin-treated and Control Human Pulmonary Microvascular Endothelial Cells
Published on: February 13, 2013
Dabigatran Monitoring Was Influenced by Thrombin Time Reagent With Different Thrombin Concentrations
11 Department of Biochemistry, Jinhua Municipal Central Hospital, Zhejiang University School of Medicine, Jinhua, Zhejiang Province, China.
Abstract:
To describe the effect of dabigatran on thrombin time (TT) reagents at different concentrations of thrombin. Pooled normal plasma enriched with dabigatran was dissolved in dimethylsulfoxide (DMSO) at concentrations of 0, 20, 50, 100, 200, 300, and 500 ng/mL. Samples with each concentration were evaluated using a semiautomatic coagulation analyzer to assess the effect of dabigatran on internal normalized ratio (INR), thromboplastin time (APTT), and TT, which were purchased from Instrument Laboratory (IL), Sysmex (SYS), and Stago (STA), respectively. Regarding INR, no reagent showed good sensitivity to increasing concentration of dabigatran, despite all reagents showing good linear response curves (P = .012). Regarding APTT, all reagents had low sensitivity to increasing dabigatran concentration, but SYS-APTT showed a better linear response curve (P = .001). Regarding TT, all reagents had a good linear response to the concentration of dabigatran; however, SYS-TT was very sensitive at low concentrations of dabigatran (0-100 ng/mL), while IL (TT-5 mL) and STA-TT were sensitive at medium concentrations of dabigatran (0-300 ng/mL), and IL (TT-2 mL) was less sensitive for a wide concentration of dabigatran (0-500 ng/mL; P = .007). Internal normalized ratio and APTT showed low sensitivity and SYS-TT showed high sensitivity to concentrations of dabigatran that were unsuitable to monitor. Both IL (TT-5 mL) and STA-TT were useful at medium concentrations of dabigatran by semiautomatic coagulation analyzer, which calculated results using the end point method of coagulation. Instrument Laboratory (TT-2 mL), which contains a higher concentration of thrombin, had better sensitivity to the concentration of dabigatran than APTT and was suitable for routine monitoring by an automatic analyzer.
More Related Videos
Related Concept Videos
Drug Concentration Versus Time Correlation
Two pivotal parameters are the minimum effective concentration (MEC) and the minimum toxic concentration (MTC). The MEC is the...
The Integrated Rate Law: The Dependence of Concentration on Time
Concentration Cells
Consider the following voltaic cell:
EDTA: Auxiliary Complexing Reagents
Acid Halides to Ketones: Gilman Reagent
As shown below, the mechanism proceeds in two steps. First, one of the alkyl groups of the reagent acts as a nucleophile and attacks the acyl carbon of the acid chloride to form a tetrahedral intermediate. This is followed by the reformation of the carbon–oxygen...
Calculating Equilibrium Concentrations
A more...

