Related Experiment Video
Updated: Jan 21, 2026

Combination of Adhesive-tape-based Sampling and Fluorescence in situ Hybridization for Rapid Detection of Salmonella on Fresh Produce
Published on: October 18, 2010
Detection of Selenocyanate in Biological Samples by HPLC with Fluorescence Detection Using König Reaction
Ryu Mochizuki1, Kyohei Higashi2, Yusuke Okamoto1
1Graduate School of Pharmaceutical Sciences, Chiba University.
Abstract:
We developed a simple and sensitive HPLC method for the determination of selenocyanate (SeCN-). The König reaction, which is generally used for the determination of cyanide and thiocyanate, was applied for the post-column detection, and using barbituric acid as a fluorogenic reagent made it possible to detect SeCN- with high sensitivity. The limits of detection (LOD) and quantification (LOQ) were 73.5 fmol and 245.1 fmol, respectively. Subsequently, the amounts of SeCN- in human blood and in cultured cell samples were analyzed, and no SeCN- was detected in human whole blood. Interestingly, we have found that some of the spiked SeCN- decomposed to cyanide in human whole blood. Ascorbic acid suppressed the decomposition of SeCN- to cyanide by reducing the ferric ion, which is typically involved in SeCN- decomposition. Then, SeCN- was detected in cultured HEK293 cells exposed to selenite. The established HPLC method with fluorescence detection of SeCN- is useful for investigating small amounts of SeCN- in biological samples.
Related Concept Videos
X-ray Diffraction of Biological Samples
According to Bragg's law, when X-rays strike the sample positioned on a stage, the rays are scattered by the electron clouds around the sample atoms. The X-ray diffraction or scattering is caused by constructive interference of the X-ray waves that reflect off the internal...
Imaging Biological Samples with Optical Microscopy
In optical microscopy, the specimen to be viewed is placed on a glass slide and clipped on the stage...
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...

