Evaluation of the cone-beam computed tomography accuracy in measuring soft tissue thickness in different areas of the
Ehsan Moudi1, Sina Haghanifar1, Maryam Johari2
1Oral Health Research Center, Institute of Health, Babol, Iran.
Purpose:
Due to the extensive use of cone-beam computed tomography (CBCT) in dentistry, especially in measuring thicknesses of hard and soft tissues, and the fact that CBCT has low contrast resolution, the aim of this study was to evaluate the accuracy of CBCT in measuring soft tissue thickness.
Materials And Methods:
In this cross-sectional study, pink baseplate wax as a soft tissue simulation was overlaid in different areas of the jaws on the dry human skull, and the probe was used to determine the thicknesses of 1, 2, 3, and 5 mm. These thicknesses were then measured accurately with a digital caliper by one person four times at interval of a week. The skull was scanned using two CBCT scanners, and the different thicknesses of wax were measured by two observers four times with a week interval. The CBCT measurements were compared with digital caliper measurements as a reference.
Results:
Statistical analysis showed no significant difference between CBCT and digital caliper measurements for thickness < 2 mm (P > 0.05).
Conclusions:
Statistically, the difference between digital caliper and CBCT measurements was < 0.1 mm, but this difference is not clinically important. The accuracy of CBCT in measuring soft tissue thickness was 0.1 mm.
More Related Videos
05:49Author Spotlight: Advancing CBCT and Digital Dental Image Integration with AI-Assisted Digitization
Published on: February 23, 2024
09:49Dual-phase Cone-beam Computed Tomography to See, Reach, and Treat Hepatocellular Carcinoma during Drug-eluting Beads Transarterial Chemo-embolization
Published on: December 2, 2013
Related Concept Videos
Computed Tomography
The technique was invented in the 1970s and is based on the principle that as X-rays pass through the body, they are absorbed or reflected at different levels. In the technique, a patient lies on a motorized platform while a computerized axial tomography (CAT) scanner rotates...
Uncertainty in Measurement: Accuracy and Precision
Imaging Studies III: Computed Tomography
Improving Translational Accuracy
Improving Translational Accuracy
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...