Related Experiment Video
Updated: Jan 21, 2026

Bacterial Detection & Identification Using Electrochemical Sensors
Published on: April 23, 2013
A Novel Bismuth-Chitosan Nanocomposite Sensor for Simultaneous Detection of Pb(II), Cd(II) and Zn(II) in Wastewater
Jae-Hoon Hwang1, Pawan Pathak2, Xiaochen Wang3
1Department of Civil, Environmental, and Construction Engineering, University of Central Florida, Orlando, FL 32816, USA.
Abstract:
A novel bismuth (Bi)-biopolymer (chitosan) nanocomposite screen-printed carbon electrode was developed using a Bi and chitosan co-electrodepositing technique for detecting multiple heavy metal ions. The developed sensor was fabricated with environmentally benign materials and processes. In real wastewater, heavy metal detection was evaluated by the developed sensor using square wave anodic stripping voltammetry (SWASV). The nanocomposite sensor showed the detection limit of 0.1 ppb Zn2+, 0.1 ppb Cd2+ and 0.2 ppb Pb2+ in stock solutions. The improved sensitivity of the Bi-chitosan nanocomposite sensor over previously reported Bi nanocomposite sensors was attributed to the role of chitosan. When used for real wastewater samples collected from a mining site and soil leachate, similar detection limit values with 0.4 ppb Cd2+ and 0.3 ppb Pb2+ were obtained with relative standard deviations (RSD) ranging from 1.3% to 5.6% (n = 8). Temperature changes (4 and 23 °C) showed no significant impact on sensor performance. Although Zn2+ in stock solutions was well measured by the sensor, the interference observed while detecting Zn2+ in the presence of Cu2+ was possibly due to the presence of Cu-Zn intermetallic species in mining wastewater. Overall, the developed sensor has the capability of monitoring multiple heavy metals in contaminated water samples without the need for complicated sample preparation or transportation of samples to a laboratory.
Related Concept Videos
Standard Electrode Potentials
Detection of Gross Error: The Q Test
Detection of Black Holes
Their closest cousins are neutron stars, which are composed almost entirely of neutrons packed against each other, making them extremely dense. A neutron star has the same mass as the Sun but its diameter is only a few kilometers. Therefore, the escape velocity from their surface is close to the speed of light.
Not until the 1960s, when the first neutron...
Difference from Background: Limit of Detection
The LOD indicates the presence or absence...
Effects of EDTA on End-Point Detection Methods
In the visual method, metal-ion indicators (metallochromic dyes), which have distinct colors in their free and complex forms, are added to the mixture to signal the titration's end point. They form stable complexes with metal ions, but these complexes are weaker than the corresponding metal–EDTA complexes. As a...
Types of Errors: Detection and Minimization
Absolute error in a measurement is the numerical difference from the true or central value. Relative error is the ratio between absolute error and the true or central value, expressed as a percentage.
Errors can be classified by source, magnitude, and sign. There are three types of errors: systematic, random, and gross.
Systematic or...

