Non-radioactive electron capture detector for gas chromatography - A possible replacement for radioactive detectors
Erik Bunert1, Birger Bernhold1, Jan N Woidtke1
1Leibniz Universität Hannover, Institute of Electrical Engineering and Measurement Technology, Department of Sensors and Measurement Technology, Appelstr. 9A, 30167 Hannover, Germany.
Abstract:
With detection limits in the low ppbv-range, electron capture detectors (ECD) are the most sensitive GC-detectors available for electron affine compounds, such as pesticides or chlorofluorocarbons. The working principle is based on the generation of free electrons at atmospheric pressure, which are usually emitted from a radioactive Ni-63 source. However, the use of radioactive materials leads to regulatory restrictions regarding purchase, operation and disposal. Recently, we introduced a novel ECD based on a non-radioactive electron source, achieving comparable detection limits, e.g. 1 ppbv (6 ng/l) for 1,1,2-trichloroethane. However, the linear range was still below that of radioactive ECDs. In addition, the detector volume was too large to be used as a GC detector. We now present an improved version of this non-radioactive ECD with significantly increased linear range of 6.5∙103 for 1,1,2-trichloroethane by implementing pulsed operation using a newly developed, autonomous control electronics. In addition, the detector volume is reduced to 100 μl, leading to faster response times, less memory effects and thus less peak broadening. The improved ECD with non-radioactive electron source reaches similar analytical performance compared to commercially available radioactive ECDs and thus can be used as a possible replacement of radioactive ECDs.
Related Concept Videos
Gas Chromatography: Types of Detectors-I
TCD is the earliest and most widely used detector that operates by measuring the changes in the thermal conductivity of the carrier gas. When a sample compound enters the detector,...
Gas Chromatography: Overview of Detectors
A non-destructive detector allows a sample to be analyzed without altering or consuming it, meaning the sample can be collected after detection for further analysis. Examples include thermal conductivity detectors and...
Gas Chromatography: Types of Detectors-II
Radioactive Decay and Radiometric Dating
Radioactivity and Nuclear Equations
A nuclide of an element has a specific number of protons and...
Types of Radioactivity
Alpha (α) decay is the emission of an α particle from the nucleus. For example, polonium-210 undergoes α decay: