Related Experiment Video
Updated: Jan 21, 2026

Determining Binding Affinity KD of Radiolabeled Antibodies to Immobilized Antigens
Published on: June 23, 2022
Influence of antibody immobilization strategy on carbon electrode immunoarrays
Mohamed Sharafeldin1, Kira McCaffrey2, James F Rusling3
1Department of Chemistry, University of Connecticut, Storrs, CT 06269, USA. james.rusling@uconn.edu and Analytical Chemistry Department, Faculty of Pharmacy, Zagazig University, Sharkia, Egypt.
Abstract:
We report here the influence of antibody immobilization strategy for protein immunosensors on screen printed carbon electrode arrays in terms of antibody binding activity, analytical sensitivity, limit of detection, and stability. Horseradish peroxidase (HRP) was the model analyte with anti-HRP immobilized on the sensors, and HRP activity was used for detection. Covalently immobilized anti-HRP antibodies on electrodes coated with chitosan, electrochemically reduced graphene oxide (rGO), and dense gold nanoparticle (AuNP) films had only 20-30% of the total immobilized antibodies active for binding. Active antibodies increased to 60% with passively adsorbed antibodies on bare electrodes, to 85% with oriented antibodies using protein A covalently immobilized on AuNP-coated carbon electrode, and to 98% when attached to protein A passively adsorbed onto bare electrodes. Passively adsorbed antibodies on bare electrodes lost activity in 1-2 days, but antibodies immobilized using other strategies remained relatively stable after 5 days. Covalent immobilization gave limits of detection (LOD) of 40 fg mL-1, while passively adsorbed antibodies or protein A on carbon electrodes had LODs 4-8 fg mL-1, but were unstable. Sensitivity was highest for antibodies covalently attached to AuNP electrodes (2.40 nA per log pg per mL) that also had highest antibody coverage, and decreased slightly when protein A on AuNP was used to orient antibodies. Passively adsorbed antibodies and oriented antibodies on protein A gave slightly lower sensitivities. Immobilization strategy or antibody orientation did not have a significant effect on LOD, but dynamic range increased as the number of active antibodies on sensor surfaces increased.
More Related Videos
09:17Reductive Electropolymerization of a Vinyl-containing Poly-pyridyl Complex on Glassy Carbon and Fluorine-doped Tin Oxide Electrodes
Published on: January 30, 2015
07:59Using Practice Testing, Public Speaking, and Source Monitoring to Examine the Influences of Learning Strategies and Stress on Episodic Memory
Published on: June 14, 2019
Related Concept Videos
The Carbon Cycle
Carbon Skeletons
Standard Electrode Potentials
Carbonation Shrinkage
The concrete's permeability is slightly reduced as calcium carbonate produced during the reaction fills its pores. Furthermore, its strength is slightly enhanced as the water released during the reaction...
Antibody Structure
Antibodies, also known as immunoglobulins (Ig), are essential players of the adaptive immune system. These antigen-binding proteins are produced by B cells and make up 20 percent of the total blood plasma by weight. In mammals, antibodies fall into five different classes, which each elicits a different biological response upon antigen binding.
The Y-Shaped Structure of Antibodies Consists of Four Polypeptide Chains
Antibodies consist of four polypeptide chains: two identical heavy...
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...