Related Experiment Video
Updated: Jan 21, 2026

Laryngeal Mask Airway LMA Placement in a Neonatal Patient Simulator Using a Non-Inflatable Supraglottic Airway SGA
Published on: July 14, 2023
Effect of monitor positioning on visual attention and situation awareness during neonatal resuscitation: a randomised
Brenda Hiu Yan Law1,2, Po-Yin Cheung1,2, Sylvia van Os2
1Department of Pediatrics, University of Alberta, Edmonton, Alberta, Canada.
Objectives:
To compare situation awareness (SA), visual attention (VA) and protocol adherence in simulated neonatal resuscitations using two different monitor positions.
Design:
Randomised controlled simulation study.
Settings:
Simulation lab at the Royal Alexandra Hospital, Edmonton, Canada.
Participants:
Healthcare providers (HCPs) with Neonatal Resuscitation Program (NRP) certification within the last 2 years and trained in neonatal endotracheal intubations.
Intervention:
HCPs were randomised to either central (eye-level on the radiant warmer) or peripheral (above eye-level, wall-mounted) monitor positions. Each led a complex resuscitation with a high-fidelity mannequin and a standardised assistant. To measure SA, situation awareness global assessment tool (SAGAT) was used, where simulations were paused at three predetermined points, with five questions asked each pause. Videos were analysed for SAGAT and adherence to a NRP checklist. Eye-tracking glasses recorded participants' VA.
Main Outcome Measure:
The main outcome was SA as measured by composite SAGAT score. Secondary outcomes included VA and adherence to NRP checklist.
Results:
Thirty simulations were performed; 29 were completed per protocol and analysed. Twenty-two eye-tracking recordings were of sufficient quality and analysed. Median composite SAGAT was 11.5/15 central versus 11/15 peripheral, p=0.56. Checklist scores 46/50 central versus 46/50 peripheral, p=0.75. Most VA was directed at the mannequin (30.6% central vs 34.1% peripheral, p=0.76), and the monitor (28.7% central vs 20.5% peripheral, p=0.06).
Conclusions:
Simulation, SAGAT and eye-tracking can be used to evaluate human factors of neonatal resuscitation. During simulated neonatal resuscitation, monitor position did not affect SA, VA or protocol adherence.
Related Concept Videos
Self-Awareness and Its Effects
Altered States of Awareness
The ingestion of substances like stimulants or hallucinogens leads to chemical alterations in the brain...
Subconsciousness and No Awareness
An illustrative example of subconscious processing is its role in problem-solving. Often, individuals...
High-Level and Low-Level Awareness
Cardiopulmonary Resuscitation I: Adult
Cardiopulmonary Resuscitation IV: Pharmacological Management