Related Experiment Video
Updated: Jan 21, 2026

Use of MRI-ultrasound Fusion to Achieve Targeted Prostate Biopsy
Published on: April 9, 2019
Prostate Contrast Enhanced Transrectal Ultrasound Evaluation of the Prostate With Whole-Mount Prostatectomy
Edouard J Trabulsi1, Brian P Calio1, Sarah I Kamel2
1Department of Urology, Thomas Jefferson University Hospital, Philadelphia, PA.
Objective:
To investigate the diagnostic accuracy of contrast enhanced transrectal ultrasound (CE-TRUS) in comparison with whole-mount radical prostatectomy specimens.
Method And Materials:
Fifty-eight subjects who underwent CE-TRUS and subsequent radical prostatectomy with whole-mount pathology were included in the study. Each patient underwent evaluation with baseline TRUS and again during CE-TRUS with intravenous infusion of perflutren lipid microsphere (Definity, Lantheus Medical Imaging, N Billerica, MA). A subjective 5 point scale was used to rate each sextant of the prostate in 3 baseline imaging modes and in 5 contrast-enhanced imaging modes. Baseline TRUS and CE-TRUS findings were compared with digitized whole-mount findings. A clustered logistic regression model was computed to compare the area under the receiver operating characteristic curve (Az) for detection of prostate cancer by various modes of ultrasound imaging.
Results:
Among the 58 whole-mount specimens, a maximum Gleason score of 6 was identified in 29 subjects, a score of 7 was identified in 24 and a score of 8 was identified in 5. The Az for baseline TRUS parameters was 0.55 for grayscale, 0.61 for color Doppler and 0.59 for power Doppler. CE-TRUS parameters demonstrated significant increases in Az with the highest Az for CE-power Doppler (0.66) and flash replenishment imaging (0.64) (P = .04 for comparison to baseline). The combination of CE-power Doppler and flash replenishment imaging resulted in improved Az compared with baseline imaging (0.70 vs 0.59, P= .006).
Conclusion:
Contrast-enhanced ultrasonography demonstrates greater diagnostic accuracy than baseline imaging. Diagnostic accuracy is further improved for "clinically significant" tumor volumes >1 cc.
More Related Videos
Related Concept Videos
Self-Evaluation: Self-Enhancement and Self-Verification
Correlations
Correlation and Causation
Correlation versus Causation
If the dependent variable increases or decreases when the independent variable increases, there is a positive or negative...
Correlation
Two variables, for example, a and b, are said to be positively correlated if both variables move in the same direction. In other words, a positive correlation exists between two variables, a and b, if:
Phase Contrast and Differential Interference Contrast Microscopy
In-phase-contrast microscopes, interference between light directly passing through a cell and light refracted by cellular components is used to create high-contrast, high-resolution images without staining. It is the oldest and simplest type of microscope that creates an image by altering the wavelengths of light rays passing through the specimen. Altered wavelength paths are created using an annular stop in the condenser. The annular stop produces a hollow cone of...
Correlation and Regression

