Related Experiment Video
Updated: Jan 21, 2026

Development of a Noninvasive, Laser-Assisted Experimental Model of Corneal Endothelial Cell Loss
Published on: April 24, 2020
Corneal Endothelial Cell Loss and Morphometric Changes 5 Years after Phacoemulsification with or without CyPass
Jonathan H Lass1, Beth Ann Benetz1, Jonathan He2
1Cornea Image Analysis Reading Center, University Hospitals Eye Institute, Department of Ophthalmology and Visual Sciences, Case Western Reserve University, Cleveland, Ohio, USA.
Purpose:
To characterize long-term changes in corneal endothelial cells after phacoemulsification with or without supraciliary Micro-Stent (Alcon) implantation in eyes with open-angle glaucoma (OAG) and visually significant cataract.
Design:
Three-year safety extension of a 2-year randomized clinical trial.
Methods:
Patients from the multicenter Study of an Implantable Device for Lowering Intraocular Pressure in Glaucoma Patients Undergoing Cataract Surgery (COMPASS) trial who underwent Micro-Stent implantation plus phacoemulsification (n = 282) or phacoemulsification alone (n = 67) were analyzed post hoc. Specular microscopy was used to assess endothelial cell loss (ECL), including changes from baseline in endothelial cell density (ECD), coefficient of variation, and percentage of hexagonal cells.
Results:
Preoperative ECDs in the microstent group (2,432.6 cells/mm2 [95% confidence interval [CI], 2,382.8-2,482.4 cells/mm2]) were similar to those in the control group (2,434.5 cells/mm2 [95% CI, 2,356.5-2,512.4 cells/mm2]) groups. ECL at months 48 and 60 was greater in the Micro-Stent group than in the control group. At month 60, the mean percent of changes in ECD was -20.4% (95% CI, -23.5% to -17.5%) in the Micro-Stent group and -10.1% (95% CI, -13.9% to -6.3%) in the control group. No statistically significant between-group changes from baseline in cellular morphology were observed. Nine adverse events were possibly related to ECL, including 3 eyes with transient focal corneal edema and 4 eyes that required Micro-Stent trimming due to protrusion.
Conclusions:
In eyes with OAG, ECL after phacoemulsification is acute and stabilizes after 3 months, whereas ECL after phacoemulsification plus Micro-Stent implantation proceeds for at least 5 years. Clinical findings associated with ECL in these eyes were uncommon (3.3% of implanted eyes), suggesting that ECL is generally a subclinical phenomenon.
Related Concept Videos
Line Loss
Line loss impacts power delivery efficiency in a balanced three-phase circuit. The symmetry in such a circuit simplifies the...
Reducing Line Loss
With a step-up transformer at the source, the voltage is increased, thereby reducing the current in the transmission lines since power loss in...
5-Number Summary
In a box plot, the minimum and maximum data values represent the lower and upper whiskers in the graph, and the median is designated as the center of the box in the chart. The first quartile and third...
Major Losses in Pipes
Fluid flow can be classified as laminar or turbulent, primarily based on the Reynolds number. This dimensionless number reflects the relative influence of inertial to viscous...
Minor Losses in Pipes
Valves play a significant role in generating minor losses by obstructing or redirecting the fluid flow. When a valve is closed or partially closed, it restricts the flow...
Energy Losses in Transformers
There are four main reasons for energy losses in transformers.
The first cause can be the high resistance of the...