Related Experiment Video
Updated: Jan 21, 2026

Treatment of Liver Metastases Using an Internal Target Volume Method for Stereotactic Body Radiotherapy
Published on: May 8, 2018
Effect of collimator angle on HyperArc stereotactic radiosurgery planning for single and multiple brain metastases
Shingo Ohira1, Tomohiro Sagawa2, Yoshihiro Ueda2
1Department of Radiation Oncology, Osaka International Cancer Institute, Osaka, Japan; Department of Medical Physics and Engineering, Osaka University Graduate School of Medicine, Suita, Japan.
Abstract:
We assessed the effect of collimator angle on the dosimetric parameters for targets and organs at risk (OARs) for collimator-optimized HA (CO-HA) and non-CO-HA (nCO-HA) plans. The nCO-HA and CO-HA plans were retrospectively generated for 26 patients (1 to 8 brain metastases). The dosimetric parameters for planning target volume (homogeneity index [HI]; conformity index [CI]; gradient index [GI]) and for OARs were compared. The modulation complexity score for volumetric modulated arc therapy (MCSV) and monitor units (MUs) were calculated. Doses were measured using the electronic portal imaging device and compared with the expected doses. Dosimetric parameters of the HI, CI, and GI for single (n = 12) and multiple (n = 14) metastases cases were comparable (p > 0.05). For multiple metastases cases, the CO-HA plan provided lower V4Gy, V12Gy, V14Gy, V16Gy for brain tissue compared to the nCO-HA plan (p < 0.05). Doses for OARs (D0.1cc) (brainstem, chiasm, Hippocampus, lens, optic nerves, and retinas) were comparable (p > 0.05). For multiple metastases cases, the CO-HA plan resulted in less complex multileaf collimator (MLC) patterns (MCSV = 0.19 ± 0.04, p < 0.01), lower MUs (8596 ± 1390 MUs, p < 0.01), and shorter beam-on time (6.2 ± 1.0 min, p < 0.01) compared to the nCO-HA plan (0.16 ± 0.04, 9365 ± 1630, and 6.7 ± 1.2 for MCSV, MUs, and beam-on time, respectively). For both treatment approach, the equivalent gamma passing rate was obtained with the 3%/3 mm and 2%/2 mm criteria (p > 0.05). The collimator optimization in the HA planning reduced doses to brain tissues and improved the treatment efficacy.
Related Concept Videos
Contact Angle
The adhesive force is the molecular force between molecules of different materials, that is, between the molecules of the solid and the liquid. The cohesive...
Sampling Plans
Random sampling is a method where each member of the population has an equal chance of being selected for the sample. It involves selecting individuals randomly, often using random number generators or lottery-type methods. For example, when analyzing the properties of a...
Bioavailability Study Design: Single Versus Multiple Dose Studies
Planning Nursing Care I
Open Angle Glaucoma: Treatment
Drugs such as carbonic anhydrase inhibitors, α2- and...
Planning Nursing Care II

