A transformation of oxygen saturation (the saturation virtual shunt) to improve clinical prediction model calibration
Guohai Zhou1, Walter Karlen2, Rollin Brant3
1Department of Statistics, University of British Columbia, Vancouver, BC, Canada. guohai.zhou@stat.ubc.ca.
Background:
The relationship between peripheral oxygen saturation (SpO2) and the inspired oxygen concentration is non-linear. SpO2 is frequently used as a dichotomized predictor, to manage this non-linearity. We propose the saturation virtual shunt (VS) as a transformation of SpO2 to a continuous linear variable to improve interpretation of disease severity within clinical prediction models.
Method:
We calculate the saturation VS based on an empirically derived approximation formula between physiological VS and SpO2. We evaluated the utility of the saturation VS in a clinical study predicting the need for facility admission in children in a low resource health-care setting.
Results:
The transformation was saturation VS = 68.864 × log10(103.711 - SpO2) - 52.110. The ability to predict hospital admission based on a dichotomized SpO2 produced an area under the receiver operating characteristic curve of 0.57, compared to 0.71 based on the untransformed SpO2 and saturation VS. However, the untransformed SpO2 demonstrated a lack of fit compared to the saturation VS (goodness-of-fit test p value < 0.0001 vs 0.098). The observed admission rates varied non-linearly with the untransformed SpO2 but varied linearly with the saturation VS.
Conclusion:
The saturation VS estimates a continuous linearly interpretable disease severity based on SpO2 and improves clinical prediction.
Related Concept Videos
Special considerations while measuring oxygen saturation
Ensuring accuracy in vital sign recordings while prioritizing patient comfort and minimizing anxiety is...
Solution Equilibrium and Saturation
Shunt Admittances
To model this effect, the method of images is employed. This method involves replacing the Earth with an image conductor that mirrors the original...
Glassware Calibration
Volumetric flasks: Volumetric flasks are designed to prepare aqueous solutions of precise volumes accurately with a calibration line on the neck. To calibrate a volumetric flask, it is important to fill it with distilled...
Instrument Calibration
Analytical Balance Calibration
An analytical balance measures mass and requires regular calibration to...
Predicting Molecular Geometry