Sören Könneker1, Katja Krockenberger2, Claudia Pieh3
1Department of Plastic, Aesthetic, Hand and Reconstructive Surgery, Hanover Medical School (MHH), Carl-Neuberg-Straße 1, 30625, Hannover, Germany. koenneker.soeren@mh-hannover.de.
Background:
Scaphoid fractures are the most common carpal fractures. They often need to be treated by surgery, where the use of a compression screw is the globally accepted gold standard. Surgeons may choose between different implant materials including titanium alloys, which remain in the body or are removed after healing. An alternative are biodegradable magnesium-based implants. Properties of magnesium alloys include high stability, osteoconductivity, potential reduction of infections and few artifacts in magnetic resonance imaging (MRI). The aim of this trial is to demonstrate non-inferiority of magnesium-based compression screws compared with titanium Herbert screws for scaphoid fractures.
Methods:
The trial is designed as a multicenter, blinded observer, randomized controlled parallel two-group post market trial. Approximately 190 patients will be randomized (1:1) with stratification by center either to titanium or magnesium-based compression screws. Follow-up is 1 year per patient. Surgical procedures and aftercare will be performed according to the German treatment guideline for scaphoid fractures. The first primary endpoint is the patient-rated wrist evaluation (PRWE) score after 6 months. The second primary endpoint is a composite safety endpoint including bone union until 6 months, no adverse device effect (ADE) during surgery or wound healing and no serious ADE or reoperation within 1 year. The third primary endpoint is the difference in change MRI artifacts over time. Non-inferiority will be investigated for primary endpoints 1 (t-test confidence interval) and 2 (Wilson's score interval) using both the full analysis set (FAS) and the per protocol population at the one-sided 2.5% test-level. Superiority of magnesium over titanium screws will be established using the FAS at the two-sided 5% test-level (Welch test) only if non-inferiority has been established for both primary endpoints. Secondary endpoints include quality of life.
Discussion:
This study will inform care providers whether biodegradable magnesium-based implants are non-inferior to standard titanium Herbert screws for the treatment of scaphoid fractures in terms of wrist function and safety. Furthermore, superiority of magnesium-based implants may be demonstrated using MRI, which is used as surrogate endpoint for screw degradation.
Trial Registration:
DRKS, DRKS00013368 . Registered Dec 04, 2017.
More Related Videos
03:53Author Spotlight: Regenerative Peripheral Nerve Interface (RPNI) Surgery in Postamputation Pain Management
Published on: March 15, 2024
04:19Minimally Invasive Treatment for Thoracolumbar Burst Fracture Using Sagittal Alignment Screws and A Trauma Reduction Device
Published on: November 8, 2024
Related Concept Videos
Self-Locking Screw
A square-threaded screw jack carrying a load is considered self-locking if the screw retains its position even after the moment applied to it is removed.
Screw: Problem Solving
To evaluate the...
Frictional Forces on Screws
A jack with a square-threaded screw is a mechanical device used to lift heavy loads by applying a force at its handle. When the force is applied, the screw turns, raising the load. The screw can...
Clinical Trials
There are four phases in a clinical trial. A phase one...
Clinical Trials: Overview
Statistical Software for Data Analysis and Clinical Trials