Related Experiment Video
Updated: Jan 21, 2026

Author Spotlight: Improving Lesion Contiguity in Pulmonary Vein Isolation via Proactive Esophageal Cooling
Published on: April 19, 2024
Clinical impact of different cut-off values in high-resolution manometry systems on diagnosing esophageal motility
Shiko Kuribayashi1,2, Katsuhiko Iwakiri3, Tomohiro Shinozaki4
1Department of Gastroenterology and Hepatology, Gunma University Graduate School of Medicine, 3-39-15 Showa-machi, Maebashi, Gunma, 371-8511, Japan. shikokuri@yahoo.co.jp.
Background:
The values of the parameters in the Chicago classification measured by a high-resolution manometry (HRM) system with the Unisensor catheter (Starlet) are significantly different from those measured by the ManoScan. The contraction vigor is categorized by values of the distal contractile integral (DCI) in the Chicago classification v3.0; however, reference values of the DCI in the Starlet and the clinical impact of the different reference values in the Starlet and ManoScan on diagnosing esophageal motility disorders are not known.
Methods:
We evaluated data from a previous report in which ManoScan and Starlet were compared in the same subjects. The DCI values in each system were compared and reference DCI values were calculated. Moreover, diagnoses assessed by Starlet using reference values in ManoScan were compared with those using calculated reference values and those assessed by ManoScan.
Results:
There was a significant positive correlation between the DCI values measured by ManoScan and those measured by Starlet (r = 0.80, p < 0.01). Based on a linear functional relationship considering measurement errors, the reference DCI values for diagnosing failed, weak and hypercontractile contraction vigor were calculated as 590.6, 1011.3 and 10,085.8 mmHg-s-cm, respectively, in the Starlet. Therefore, the proposed reference values in the Starlet were 500, 1000 and 10,000 mmHg-s-cm, respectively. When the reference values in the ManoScan were used in the Starlet data, approximately 30% of subjects were diagnosed inappropriately. This issue was resolved using the proposed reference values in the Starlet.
Conclusion:
Recognizing systemic differences in HRM systems is important.
Related Concept Videos
Gastrointestinal Motility Disorders
Esophageal Strictures-II: Clinical Features and Management
Healthcare providers should gather a comprehensive medical history and conduct a physical examination for diagnosis. If esophageal stricture is...
Esophageal Perforation-II: Clinical Manifestations and Management
Clinical Manifestations:
Esophageal Varices-II: Clinical Features and Management
In the initial assessment, a thorough review of the patient's medical history is vital to identify risk factors such as liver disease, alcohol...
Biodiversity and Human Values
Professional Values
The values that are the foundation of the nursing profession are altruism, autonomy, human dignity, and social justice.
First, altruism refers to the concern for the welfare and well-being of others without personal...

