Related Experiment Video
Updated: Jan 21, 2026

Separating Beads and Cells in Multi-channel Microfluidic Devices Using Dielectrophoresis and Laminar Flow
Published on: February 4, 2011
Dielectrophoresis Multipath Focusing of Microparticles through Perforated Electrodes in Microfluidic Channels
Anas Alazzam1,2, Mohammad Al-Khaleel3,4, Mohamed Kamel Riahi3
1Mechanical Engineering Department, Khalifa University, Abu Dhabi 127788, UAE.
Abstract:
This paper presents focusing of microparticles in multiple paths within the direction of the flow using dielectrophoresis. The focusing of microparticles is realized through partially perforated electrodes within the microchannel. A continuous electrode on the top surface of the microchannel is considered, while the bottom side is made of a circular meshed perforated electrode. For the mathematical model of this microfluidic channel, inertia, buoyancy, drag and dielectrophoretic forces are brought up in the motion equation of the microparticles. The dielectrophoretic force is accounted for through a finite element discretization taking into account the perforated 3D geometry within the microchannel. An ordinary differential equation is solved to track the trajectories of the microparticles. For the case of continuous electrodes using the same mathematical model, the numerical simulation shows a very good agreement with the experiments, and this confirms the validation of focusing of microparticles within the proposed perforated electrode microchannel. Microparticles of silicon dioxide and polystyrene are used for this analysis. Their initial positions and radius, the Reynolds number, and the radius of the pore in perforated electrodes mainly conduct microparticles trajectories. Moreover, the radius of the pore of perforated electrode is the dominant factor in the steady state levitation height.
Related Concept Videos
Esophageal Perforation-I: Introduction
The location of esophageal perforation can vary, occurring anywhere along the esophagus....
Ion Channels
Ion channels are specialized integral membrane proteins on the plasma membrane that allow...
Standard Electrode Potentials
Esophageal Perforation-II: Clinical Manifestations and Management
Clinical Manifestations:
Electrodes: Overview
There are two main types of electrodes in electrochemical cells. The first type, known as the working or indicator electrode, has a potential that is sensitive to the analyte's concentration and reacts to changes in...
Focusing of Light in the Eye