Related Experiment Video
Updated: Jan 21, 2026

A Simple and Low-cost Assay for Measuring Ambulation in Mouse Models of Muscular Dystrophy
Published on: December 29, 2017
Body temperature measurement in ambulance: a challenge of 21-st century?
Paweł Podsiadło1, Tomasz Darocha2, Sylweriusz Kosiński3
1Department of Emergency Medicine, Jan Kochanowski University, IX Wieków Kielc, 19, Kielce, Poland.
Background:
Some crucial decisions in treatment of hypothermic patients are closely linked to core body temperature. They concern modification of resuscitation algorithms and choosing the target hospital. Under- as well as over-estimation of a patient's temperature may limit his chances for survival. Only thermometers designed for core temperature measurement can serve as a guide in such decision making. The aim of the study was to assess whether ambulance teams are equipped properly to measure core temperature.
Methods:
A survey study was conducted in collaboration with the Health Ministry in April 2018. Questionnaires regarding the model, number, and year of production of thermometers were sent to each pre-hospital unit of the National Emergency Medical System in Poland.
Results:
A total of 1523 ground ambulances are equipped with 1582 thermometers. 53.57% are infrared-based ear thermometers, 23.02% are infrared-based surface thermometers, and 20.13% are conventional medical thermometers. Only 3.28% of devices are able to measure core body temperature. Most of analyzed thermometers (91.4%) are not allowed to operate in ambient temperature below 10 °C.
Conclusions:
There are only 3.28% of ground ambulances that are able to follow precisely international guidelines regarding a patient's core body temperature. A light, reliable thermometer designed to measure core temperature in pre-hospital conditions is needed.
More Related Videos
04:34Mouse Body Temperature Measurement Using Infrared Thermometer During Passive Systemic Anaphylaxis and Food Allergy Evaluation
Published on: September 14, 2018
09:18Measurements of Motor Function and Other Clinical Outcome Parameters in Ambulant Children with Duchenne Muscular Dystrophy
Published on: January 12, 2019
Related Concept Videos
Equipments Used to Measure Body Temperature
Glass-bulb Thermometer:
Glass-bulb thermometers are hollow glass tubes with a bulb tip containing liquid such as ethanol or mercury. Historically, glass bulb mercury thermometers were the standard device to measure body temperature. Today, mercury thermometers are prohibited in many countries due to the hazardous effects of mercury and the risk of exposure if the glass bulb breaks. In general,...
Body Temperature
The average body temperature is approximately 37°C (98.6°F) and typically ranges from 36.1–37.2°C...
Body Temperature
Factors Affecting Body Temperature
Factors may include:
Increased Body Temperature
Decreased Body Temperature