Related Experiment Video
Updated: Jan 21, 2026

Synthesis of Soft Polysiloxane-urea Elastomers for Intraocular Lens Application
Published on: March 8, 2019
Performance of a New-Generation Extended Depth of Focus Intraocular Lens-A Prospective Comparative Study
Madhivanan Nivean1, Pratheeba Devi Nivean1, Jagadeesh Kumar Reddy2
1MN Eye hospital, Chennai, India.
Purpose:
The aim was to study the visual performance of a new refractive extended depth of focus (EDOF) intraocular lens (IOL).
Design:
Prospective, comparative study.
Methods:
Consenting patients with age-related cataract willing for bilateral cataract surgery within 2 weeks were implanted with the Supraphob EDOF IOL and those willing for 1 eye surgery were implanted with a monofocal IOL. The uncorrected and best-corrected distance, intermediate and near visual acuity, and contrast sensitivity were evaluated at 1 and 3 months postoperatively. We also inquired about glare, halos, difficulties in night driving, requirement for spectacles, and overall satisfaction with vision.
Results:
The Supraphob EDOF group (n = 72 eyes) and the monofocal IOL group (n = 54 eyes) were comparable with respect to all preoperative parameters including biometry, visual acuity, and cataract status. The mean age of participants was 58.4 ± 10.6 years. Both groups had similar distance vision but the EDOF group had significantly better intermediate (0.2 ± 0.2 logMAR vs 0.75 ± 0.19 logMAR, P < 0.001) and near vision (median = N6 vs N12, P < 0.001) compared to the monofocal group at 3 months. The contrast sensitivity was similar in both groups. Patients in the EDOF IOL group had much greater satisfaction for intermediate and near vision. Less than 10% patients reported glare, halos, and difficulty in driving at night in the EDOF group.
Conclusions:
The Supraphob EDOF IOL was effective in improving the distance, intermediate and near vision in majority of patients, and retained good contrast sensitivity with most patients reporting excellent satisfaction.
More Related Videos
Related Concept Videos
Uniform Depth Channel Flow
Depth Perception and Spatial Vision
Uniform Depth Channel Flow: Problem Solving
Comparing Copy Number Variations and SNPs
Copy number variations or CNVs are the structural variations that cover more than 1kb of DNA sequence. The single nucleotide polymorphism (SNP), on the other hand, is a single nucleotide change or a point mutation that is found in more than 1%...
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Gravitational Potential Energy for Extended Objects