Quantification of coagulation factor VIII in human plasma with liquid chromatography tandem mass spectrometry using a
Mohsin El Amrani1, Anouk A M Donners2, Gerard Graat1
1Department of Clinical Chemistry, University Medical Center Utrecht, Utrecht, the Netherlands.
Abstract:
Patients with hemophilia A are currently diagnosed and monitored by measuring the activity of coagulation factor VIII (FVIII) in plasma mostly with the one-stage clotting assay (OSA). Although the OSA is routinely available in many clinical laboratories, it has in some circumstances relatively low sensitivity and specificity. Therefore, the FVIII activity as a biomarker does not always correlate with the bleeding phenotype. Therefore, we have developed a liquid chromatography tandem mass spectrometry method to quantify the concentration of coagulation FVIII in plasma which would allow us to investigate the relation between FVIII plasma concentration, FVIII activity and bleeding tendency in future studies. LC-MS/MS method was set up by firstly dissociation Von Willebrand factor (VWF) from coagulation factor VIII by triggering the coagulation cascade to occur thus generating active factor VIII (FVIIIa). FVIIIa was then selectively extracted by means of immunoaffinity interaction using anti-FVIII camelid nanobody, after which FVIIIa was eluted, heat denatured and trypsin digested. Finally, a FVIII specific peptide was used as a surrogate for quantification by mass spectrometry. Critical method parameters such as antibody amount, incubation time, sample volume and type of streptavidin 96 well plate were optimized. The method was validated according to European Medicines Agency (EMA) guidelines where an LLOQ of 1 ng/mL was obtained using 50 μL of citrate plasma sample. Within-run and between-run accuracy and precision for quality control (QC) samples, LLOQ (1 ng/mL), QC Low (5 ng/mL), QC Med (150 ng/mL), QC High (300 ng/mL) were within the threshold of 15% relative standard deviation (RSD) and Bias. The selective immunoaffinity method which was used in combination with a highly sensitive mass spectrometer allowed for an unpresented LLOQ of 1 ng/mL utilizing 50 μL plasma sample. This method will be used to investigate the beneficial value of FVIII plasma concentration which may be used in conjunction with FVIII activity for patient diagnosis and dosage optimization.
More Related Videos
08:56Quantitative Analysis of the Cellular Lipidome of Saccharomyces Cerevisiae Using Liquid Chromatography Coupled with Tandem Mass Spectrometry
Published on: March 8, 2020
08:14Extraction of Non-Protein Amino Acids from Cyanobacteria for Liquid Chromatography-Tandem Mass Spectrometry Analysis
Published on: December 9, 2022
Related Concept Videos
Tandem Mass Spectrometry
Peptide Identification Using Tandem Mass Spectrometry
This technique helps gather information regarding the protein from which the peptide was obtained and to study the peptides’ amino acid sequence. Identifying peptides from a complex mixture is an important component of the growing field of...
Gas Chromatography–Mass Spectrometry (GC–MS)
A gas chromatograph consists of a long, narrow capillary column with a polysiloxane coating on the inner wall....
Inductively Coupled Plasma-Mass Spectrometry (ICP-MS): Interferences
Inductively Coupled Plasma–Mass Spectrometry (ICP–MS): Overview
High-Performance Liquid Chromatography: Introduction
In HPLC, two phases play a critical role in the separation process: