Appropriate Mother Wavelets for Continuous Gait Event Detection Based on Time-Frequency Analysis for Hemiplegic and

Ning Ji1,2, Hui Zhou3, Kaifeng Guo4

  • 1College of Medicine and Biological Information Engineering, Northeastern University, Shenyang 110819, China.

Related Concept Videos

Continuous -time Fourier Transform01:11

Continuous -time Fourier Transform

The Fourier series is instrumental in representing periodic functions, offering a powerful method to decompose such functions into a sum of sinusoids. This technique, however, necessitates modification when applied to nonperiodic functions. Consider a pulse-train waveform consisting of a series of rectangular pulses. When these pulses have a finite period, they can be accurately represented by a Fourier series. Yet, as the period approaches infinity, resulting in a single, isolated pulse, the...
849
Basic Continuous Time Signals01:22

Basic Continuous Time Signals

Basic continuous-time signals include the unit step function, unit impulse function, and unit ramp function, collectively referred to as singularity functions. Singularity functions are characterized by discontinuities or discontinuous derivatives.
The unit step function, denoted u(t), is zero for negative time values and one for positive time values, exhibiting a discontinuity at t=0. This function often represents abrupt changes, such as the step voltage introduced when turning a car's...
671
Sampling Continuous Time Signal01:11

Sampling Continuous Time Signal

In signal processing, a continuous-time signal can be sampled using an impulse-train sampling technique, followed by the zero-order hold method. Impulse-train sampling involves the use of a periodic impulse train, which consists of a series of delta functions spaced at regular intervals determined by the sampling period. When a continuous-time signal is multiplied by this impulse train, it generates impulses with amplitudes corresponding to the signal's values at the sampling points.
In the...
696
Time and frequency -Domain Interpretation of PI Control01:27

Time and frequency -Domain Interpretation of PI Control

Proportional-Integral (PI) controllers are essential in many control systems to improve stability and performance. They are commonly used in everyday devices like thermostats to enhance system damping and reduce steady-state error. When the zero in the controller's transfer function is optimally placed, the system benefits significantly in terms of stability and accuracy.
Acting as a low-pass filter, the PI controller slows the system's response and extends settling times. This requires...
403
BIBO stability of continuous and discrete -time systems01:24

BIBO stability of continuous and discrete -time systems

System stability is a fundamental concept in signal processing, often assessed using convolution. For a system to be considered bounded-input bounded-output (BIBO) stable, any bounded input signal must produce a bounded output signal. A bounded input signal is one where the modulus does not exceed a certain constant at any point in time.
To determine the BIBO stability, the convolution integral is utilized when a bounded continuous-time input is applied to a Linear Time-Invariant (LTI) system....
892
Time and frequency -Domain Interpretation of Phase-lead Control01:24

Time and frequency -Domain Interpretation of Phase-lead Control

Phase-lead controllers are commonly used in various control systems to enhance response speed and stability. Adjusting the brightness on a television screen offers a practical example of phase-lead control. When contrast is enhanced, a phase-lead controller is employed. Mathematically, phase-lead control is identified when the first parameter is smaller than the second.
The design of phase-lead control involves the strategic placement of poles and zeros to balance steady-state error and system...
435