Intraobserver and interobserver reliability in sonographic size measurements of gallbladder polyps
Seul Bi Lee1,2, Yedaun Lee3, Seung Jin Kim1
1Department of Radiology, Inje University College of Medicine, Haeundae Paik Hospital, Haeundae-ro 875, Haeundae-gu, Busan, Republic of Korea.
Objectives:
To evaluate the intraobserver and interobserver reliability of gallbladder polyp measurements using transabdominal US and the factors that affect reliability.
Methods:
From November 2017 to February 2018, two radiologists measured the maximum diameter of 91 gallbladder polyps using transabdominal US. Intraobserver and interobserver agreement were determined using 95% Bland-Altman limits of agreement and intraclass correlation coefficients (ICCs). The effects of image settings, polyp location, and polyp size were evaluated by comparing ICCs using z tests.
Results:
The intraobserver agreement rates were 0.960 (95% confidence interval [CI], 0.939-0.973) for observer 1 and 0.962 (95% CI, 0.943-0.975) for observer 2. The ICCs between the two observers were 0.963 (95% CI, 0.926-0.979) for the first measurement and 0.973 (95% CI, 0.950-0.984) for the second measurement. The 95% limits of agreement on repeated measurements were 22.3-25.2% of the mean, and those between the two observers were 25.5-34.2% of the mean. ICCs for large polyps (≥ 5 mm) were significantly higher than those for small polyps (< 5 mm). There were no significant differences in the ICCs between image settings and polyp location.
Conclusions:
Polyp size measurements using transabdominal US are highly repeatable and reproducible. Polyp size significantly affects the reliability of measurement. Diameter changes of approximately less than 25% may fall within the measurement error; this should be considered while interpreting the change in size during follow-up US, especially for small polyps.
Key Points:
• Gallbladder polyp size measurement using transabdominal US is highly repeatable and reproducible. • Diameter changes of approximately less than 25% should be interpreted carefully, especially in small polyps.
Related Concept Videos
Gallbladder
The gallbladder's anatomy consists of three regions: the fundus, body, and neck. Extending from the neck, the cystic duct joins...
Reliability and Validity
Diseases of the Liver and Gallbladder
Cirrhosis is characterized by the scarring of hepatic lobules in the liver, which are replaced by fibrous tissue, affecting the liver's normal functioning. NAFLD, on the other hand, is caused by an excessive build-up of fat in the liver, not...
Distribution Reliability and Automation
Cell Size
Surface Area
Cells can take in nutrients and water via diffusion through the plasma membrane itself or through specific channels in the membrane. The area of the membrane surrounding...
Brick Sizes
Modular bricks are the most common type and are sized to include the mortar joint, which is essential for...