Related Experiment Video
Updated: Jan 21, 2026

Improved Rodent Model of Myocardial Ischemia and Reperfusion Injury
Published on: March 7, 2022
Improved prediction of HIT in the SICU using an improved model of the Warkentin 4-T system: 3-T
Matthew B Bloom1, Jeffrey Johnson1, Oksana Volod2
1Department of Surgery, Cedars-Sinai Medical Center, Los Angeles, CA, 90048, USA.
Background:
The Warkentin 4-T scoring system for determining the pretest probability of heparin-induced thrombocytopenia (HIT) has been shown to be inaccurate in the ICU and does not take into account body mass index (BMI).
Methods:
Prospectively collected data on patients in the surgical and cardiac ICU between January 2007 and February 2016 who were presumed to have HIT by clinical suspicion were reviewed. Patients were categorized into 3 BMI groups and assigned scores: Normal weight, overweight, and obese. Multivariate analyses were used to identify independent predictors of HIT.
Results:
A total of 523 patients met inclusion criteria. Multivariate analysis showed that only BMI, Timing, and oTher variables were independently associated with HIT. This new 3-T model was better than a five-component model consisting of the entire 4-T scoring system plus BMI (AUC = 0.791).
Conclusions:
Incorporating patient 'T'hickness into a pretest probability model along with platelet 'T'iming and the exclusion of o'T'her causes of thrombocytopenia yields a simplified "3-T" scoring system that has increased predictive accuracy in the ICU.
Related Concept Videos
Improving Translational Accuracy
Improving Translational Accuracy
Predicting Molecular Geometry
Prediction Intervals
However, the point estimate is most likely not the exact value of the population parameter, but close to it. After calculating point estimates, we construct interval estimates, called confidence intervals or prediction intervals. This prediction interval comprises a range of values unlike the point estimate and is a better predictor of the observed sample value, y.
End Point Prediction: Gran Plot
For potentiometric titration, the Gran plot is created by plotting...
Sensitivity, Specificity, and Predicted Value
Sensitivity is the...