Optimal design of a simulated-moving-bed chromatographic process for high-purity separation of acetoin from
Chung-Gi Lee1, Cheol Yeon Jo1, Ye Jin Song1
1Department of Chemical Engineering, Hanyang University, Haengdang-dong, Seongdong-gu, Seoul, 04763, South Korea.
Abstract:
For the high-purity production of acetoin or 2,3-butanediol (BD) from related fermentation processes, it is essential to accomplish a detailed separation between acetoin and BD in an economical mode. To address this issue, we aimed to develop a highly-efficient simulated-moving-bed (SMB) process for the continuous-mode separation of acetoin from BD with high purity and small loss. As a first step for this task, the adsorption and mass-transfer parameters of acetoin and BD on a proven adsorbent were estimated while assuming that BD isomers (meso-BD and DL-BD) would be identical in adsorption and mass-transfer behaviors. The resultant parameters from such estimation were applied to the optimal design of the acetoin-BD separation SMB. The designed SMB was then experimentally investigated, which revealed that some sign of BD isomerism occurred in the SMB column-profile data and thus had an adverse effect on the SMB separation performance. To resolve this problem, the individual parameters of BD isomers were determined on the basis of the SMB column-profile data and an inverse-method principle. The resulting parameters of BD isomers were used in the re-design of the target SMB, which was then experimentally checked for its separation performance. It was confirmed that such SMB re-designed in consideration of BD isomerism was quite effective in the continuous-mode separation of acetoin from BD with high purity (> 99.2%) and small loss (< 1.52%).
Related Concept Videos
Optimizing Chromatographic Separations
Band broadening refers to spreading solute bands as they travel through the column. This broadening can impact resolution. Plate height (H) represents the length required for one theoretical plate. A lower plate height corresponds to...
Capillary Beds
Capillaries connect arterioles, small branches of arteries, to venules,...
Chromatographic Resolution
The effectiveness of separation can be evaluated by determining the level of separation between two neighboring peaks in a chromatogram, which represents the individual components of a sample.
In chromatography,...
Chromatographic Methods: Terminology
Chromatographic Methods: Classification
Chromatographic techniques are typically named by...
What is a Mode?
There can be more than one mode in a data set if multiple values have the same highest frequency. For instance, suppose that the Statistics exam scores of 20 students are: 50; 53; 59; 59; 63; 63; 72; 72; 72; 72; 72; 76; 78; 81; 83; 84; 84; 84; 90; 93. Here, the mode is 72, as it occurs most frequently, five times.
A data set with two modes is called bimodal. For example,...