Related Experiment Video
Updated: Jan 21, 2026

Analysis and Specification of Starch Granule Size Distributions
Published on: March 4, 2021
Hydroxyethyl starch 130/0.4 (6%) and succinylated gelatine (4%) interfere with refractometry in dogs with
Elodie Yam1, Corrin J Boyd1, Giselle Hosgood1
1Comparative Health Research Group, School of Veterinary and Life Sciences, Murdoch University, WA, Australia.
Objective:
To determine if low molecular weight synthetic colloid fluids administered to dogs interfere with refractometric estimates of total plasma protein (TPPr) and urine osmolality (UOsm).
Study Design:
Experimental study.
Animals:
Eighteen healthy Greyhound dogs.
Methods:
Anaesthetized Greyhounds subjected to haemorrhage for 60 minutes were given 80 mL kg-1 of Plasma-Lyte 148 (CRYST), or 20 mL kg-1 of hydroxyethyl starch 130/0.4 (HES) or succinylated gelatine (GELO) (n = 6 per group) intravenously over 20 minutes. Refractometric (TPPr) and biuret total plasma protein (TPPb) were measured before haemorrhage (Baseline), at end of shock (Shock), immediately (T20), then 40 minutes (T60), 100 minutes (T120) and 160 minutes (T180) after fluid administration. Urine specific gravity (USG) and UOsm were measured at all time points except T20. Estimated UOsm (eUOsm) was calculated from USG. Bias and limits of agreement (LOA) for TPPr versus TPPb, and eUOsm versus UOsm were calculated at each time point.
Results:
For dogs given CRYST and GELO, median TPPr and TPPb decreased in parallel, with a small consistent TPP bias (CRYST range of bias, 0.38-0.67 g dL-1; GELO range of bias, 0.42-0.58 g dL-1). Dogs given HES showed divergence between median TPPr and TPPb after T20, with a peak bias at T20 of 1.62 g dL-1 (LOA 1.29-1.95). Dogs given HES and GELO had markedly increased USG [HES peak median USG at T180 of 1.119 (Q1-Q3 1.103-1.122); GELO peak median USG at T120 of 1.114 (Q1-Q3 1.082-1.119)], with large increases in bias between eUOsm and UOsm [HES peak bias at T60 of 2995 mOsm kg-1 (LOA 2032-3958 mOsm kg-1); GELO peak bias at T120 of 2465 mOsm kg-1 (LOA 940-3990 mOsm kg-1)].
Conclusions And Clinical Relevance:
Administration of HES and GELO to dogs with haemorrhagic shock interferes with refractometric measurements for at least 3 hours after administration.
More Related Videos
08:59The Other End of the Leash: An Experimental Test to Analyze How Owners Interact with Their Pet Dogs
Published on: October 13, 2017
07:04Measuring Uptake of the Glucose Analog, 6-(N-(7-Nitrobenz-2-Oxa-1,3-Diazol-4-yl)Amino)-6-Deoxyglucose, in Intact Murine Neural Retina
Published on: March 14, 2025
Related Concept Videos
Interference and Diffraction
RNA Interference
This process occurs naturally in cells, often through the activity of genomically-encoded microRNAs. Researchers can take advantage of this mechanism by introducing synthetic RNAs to deactivate specific genes for research or therapeutic purposes. For example, RNAi could be used...
Shock Waves
When the source's speed approaches the speed of sound, constructive interference between successive wavefronts emitted by the source occurs immediately behind it. Initially, scientists believed that this constructive interference would result in such high...
Interference and Decay
Interference occurs when competing memories hinder the retrieval of particular information. It can be classified into two types: proactive and retroactive interference. Proactive...
Interference: Path Lengths
Two special sources may be considered when they are in phase. This can be easily achieved by feeding the two sources from the same source. An example would be synchronizing the two speakers by feeding them with the same source, such as the sound waves produced by a tuning fork. This setup ensures that the two sources have the same frequency and are...
Interference and Superposition of Waves
Interference occurs in mechanical waves, such as sound waves, waves on a string, and surface water waves. Mechanical waves correspond to the physical displacement of particles. Hence,...