AcrySof IQ PanOptix Intraocular Lens Versus Extended Depth of Focus Intraocular Lens and Trifocal Intraocular Lens: A
Rachapalle Reddi Sudhir1, Arindam Dey2, Shovan Bhattacharrya2
1Medical Research Foundation, Sankara Nethralaya, Chennai, Tamil Nadu, India.
Abstract:
AcrySof IQ PanOptix Model TFNT00 (Alcon Laboratories, Fort Worth, TX) is a 1-piece aspheric hydrophobic presbyopia-correcting intraocular lens (IOL) launched in 2015. Unlike traditional trifocal IOLs that usually have an intermediate focal point of 80 cm, the PanOptix IOL is designed to have an intermediate focal point of 60 cm (arms-length), a more natural and comfortable working distance to perform functional tasks on computers, laptops, mobiles, among others. The non-apodized PanOptix IOL uses the ENhanced LIGHT ENergy (ENLIGHTEN; Alcon Laboratories, Fort Worth, TX) optical technology that provides high (88%) utilization of light energy, low dependence on pupil size in all lighting conditions, and a more comfortable near-to-intermediate range of vision than traditional trifocal IOLs. This review provides an overview of the clinical performance of the PanOptix IOL and discusses it in the context of other commercially available trifocal IOLs, FineVision Micro F (PhysIOL, Liege, Belgium), the AT LISA tri 839MP (Carl Zeiss Meditec AG, Jena, Germany) and the extended depth of focus IOL, TECNIS Symfony (Abbott Medical Optics, Santa Ana, CA). A literature search was performed in the PubMed database to identify studies that have assessed the visual and other clinical outcomes with the PanOptix IOL. In total, 12 studies were included in this review article. Overall, the clinical evidence suggests that in general good visual outcomes, along with a high degree of spectacle independence, are achieved in patients implanted with the PanOptix, FineVision, AT LISA and Symfony IOLs. However, every MIOL has its benefits and limitations, which along with patient's needs and clinical conditions are important factors to consider while selecting an IOL to achieve best possible post-operative outcomes.
Related Concept Videos
Clinical Trials: Overview
Uniform Depth Channel Flow
Depth Perception and Spatial Vision
Uniform Depth Channel Flow: Problem Solving
Assessment of Ventilation II: Respiratory Depth and Rhythm
Respiratory depth measures the volume of air inhaled or exhaled during a breath. It can vary from shallow to deep and typically remains consistent when a person is at rest or asleep. Occasionally, individuals will automatically inhale deeply, known as sighing, which inflates the lungs with more air than normal breathing.
To assess respiratory depth, observe the degree of chest excursion or movement:
Gravitational Potential Energy for Extended Objects