Initial clinical experience of a steerable access device for EUS-guided biliary drainage
Related Experiment Video
Updated: Jan 21, 2026

Endoscopic Ultrasound-Guided Biliary Drainage: Endoscopic Ultrasound-Guided Hepaticogastrostomy in Malignant Biliary Obstruction
Published on: March 25, 2022
Marvin Ryou1, Petros C Benias2, Vivek Kumbhari3
1Division of Gastroenterology, Hepatology and Endoscopy, Brigham and Women's Hospital, Harvard Medical School, Boston, Massachusetts, USA.
Background And Aims:
EUS-guided biliary drainage (EUS-BD) has been used as a rescue procedure after failed endoscopic retrograde cholangiography (ERC), and there is growing interest in EUS-BD as a primary therapy for distal malignant biliary obstruction. After EUS-guided needle puncture of an obstructed bile duct, directional control of wire advancement remains an area of need, potentially addressed by a new steerable EUS access system. The aim of this study was to evaluate the safety and efficacy of this novel steerable access system in patients undergoing EUS-BD after failed ERC.
Methods:
We performed a retrospective study of prospectively acquired data at 3 tertiary academic hospitals. Consecutive patients who had failed ERC followed by EUS-BD using the access device were included. Primary outcomes were safety and technical feasibility (successful completion of EUS-BD). Secondary outcomes were clinical success (75% improvement in liver function tests at 30 days) and device performance.
Results:
Twenty-two consecutive patients underwent EUS-BD between October 10, 2018 and March 3, 2019. Needle puncture and selective wire advancement in the intended direction were both successful in 100% of cases (22/22). Technical success was 95% (21/22). Fifty-nine percent (13) underwent rendezvous, 32% (7) underwent choledochoduodenostomy, and 4.5% (1) underwent hepaticogastrostomy. One patient (4.5%) underwent percutaneous transhepatic cholangiography. There were no cases of wire shearing. The adverse event rate was 4.5% (mild pancreatitis in 1 patient). There was no bile leak, bleeding, or death at 30 days' follow-up.
Conclusions:
This first clinical experience with a steerable access system for EUS-BD suggests it is safe and effective, particularly with regard to controlling direction of wire advancement.
More Related Videos
Related Concept Videos
Initiation of Translation
First, the initiator tRNA must be selected from the pool of elongator tRNAs by eukaryotic initiation factor 2 (eIF2). The initiator tRNA (Met-tRNAi) has conserved sequence elements including modified bases at...
Initiation of Translation
Cavity Drainage and Flashings in Masonry walls
Weep holes, strategically placed at the base of the cavity, are critical for draining accumulated water. These openings are created by leaving head...
Transcription Initiation
The promoters and enhancers and their accessory proteins allow tight regulation of...
S-Cdk Initiates DNA Replication
Two states at the origin of replication
In eukaryotes, the initiation of replication occurs at many sites on the chromosomes, called the origins of...
What is an Experiment?