Related Experiment Video
Updated: Jan 21, 2026

Author Spotlight: Advancing Rapid Detection of Respiratory Pathogens Using Microfluidic Chip
Published on: March 29, 2024
Lab in a Pasteur pipette: low-cost, rapid and visual detection of Bacillus cereu using denaturation bubble-mediated
Shuai Liu1, Manman Wei1, Rui Liu1
1Shandong Provincial Key Laboratory of Biochemical Engineering, College of Marine Science and Biological Engineering, College of Environment and Safety Engineering, Qingdao University of Science and Technology, Qingdao, 266042, PR China.
Abstract:
Driven by a bright prospect for rapid, portable and cost-effective point-of-care testing, an assembled Pasteur pipette device to integrate nucleic acid extraction, amplification and detection was developed to detect B. cereus in a sample-to-answer format. Denaturation Bubble-mediated Strand Exchange Amplification (SEA) was chosen to perform isothermal amplification because it requires only a pair of primers and one Bst DNA polymerase. The established SEA can detect as low as 1.0 × 10-13 M genomic DNA of B. cereus, which was comparable with the previously reported method for B. cereus detection. The assembled Pasteur pipette allows sample-to-answer diagnostic in a simple, low-cost, portable, and disposable format. The inherent function of Pasteur pipette enables direct liquid handling without the need of extra pipettes, syringes or pumps. Visual readout was achieved by using a pH sensitive dye, further simplifying result judgment process. The detection limit for B. cereus is 1.0 × 104 CFU/mL in pure cultures, while the detection limit in artificially contaminated milk is 1.0 × 105 CFU/mL without enrichment and 1.0 × 100 CFU/mL following 12 h enrichment. Considering that typical cell counts in food samples associated to food poisoning are 1.0 × 105 to 1.0 × 108 CFU per gram/milliliter B. cereus, our Pasteur pipette is enough sensitive for answer-to-sample diagnosis of B. cereus even directly from foods without enrichment. The whole diagnostic procedure could be completed within 50 min, dramatically decreasing the detection time. In a word, the assembled Pasteur pipette device, combined with a homemade metal bath, possesses great potential for sample-to-answer application in resource-limited settings.
More Related Videos
Related Concept Videos
RACE - Rapid Amplification of cDNA Ends
Social Exchange Theory
Protein Denaturation
Lagging Strand Synthesis
There are several major differences between synthesis of the leading strand and synthesis of the lagging strand. 1) Leading strand synthesis happens in the direction of replication fork opening, whereas lagging strand synthesis happens in the...
Excess Pressure Inside a Drop and a Bubble
Gas Exchange and Transport