Related Experiment Video
Updated: Jan 20, 2026

Author Spotlight: Enhancing Skin Model Diversity with Cost-Effective 3D Cellular Models
Published on: October 20, 2023
Building Three-Dimensional Intracranial Aneurysm Models from 3D-TOF MRA: a Validation Study
Turker Acar1,2,3, Asli Beril Karakas2, Mehmet Asim Ozer2
1Department of Radiology, University of Health Sciences Bozyaka Education and Training Hospital, Izmir, Turkey.
Abstract:
To create realistic three-dimensional (3D) vascular models from 3D time-of-flight magnetic resonance angiography (3D-TOF MRA) of an intracranial aneurysm (IA). Thirty-two IAs in 31 patients were printed using 3D-TOF MRA source images from polylactic acid (PLA) raw material. Two observers measured the maximum IA diameter at the longest width twice separately. A total mean of four measurements as well as each observer's individual average MRA lengths were calculated. After printing, 3D-printed anatomic models (PAM) underwent computed tomography (CT) acquisition and each observer measured them using the same algorithm as applied to MRA. Inter- and intra-observer consistency for the MRA and CT measurements were analyzed using the intraclass correlation coefficient (ICC) and a Bland-Altman plot. The mean maximum aneurysm diameter obtained from four MRA evaluations was 8.49 mm, whereas it was 8.83 mm according to the CT 3D PAM measurement. The Wilcoxon test revealed slightly larger mean CT 3D PAM diameters than the MRA measurements. The Spearman's correlation test yielded a positive correlation between MRA and CT lengths of 3D PAMs. Inter and intra-observer consistency were high in consecutive MRA and CT measurements. According to Bland-Altman analyses, the aneurysmal dimensions obtained from CT were higher for observer 1 and observer 2 (a mean of 0.32 mm and 0.35 mm, respectively) compared to the MRA measurements. CT dimensions were slightly overestimated compared to MRA measurements of the created models. We believe the discrepancy may be related to the Laplacian algorithm applied for surface smoothing and the high slice thickness selection that was used. However, ICC provided high consistency and reproducibility in our cohort. Therefore, it is technically possible to produce 3D intracranial aneurysm models from 3D-TOF MRA images.
Related Concept Videos
Aneurysm II: Clinical Manifestations and Diagnostic Studies
Reliability and Validity
Aneurysm I: Introduction
Movement Joints in Buildings
The simplest type of movement joints, working joints, are...
MALDI-TOF Mass Spectrometry
Types of Building Stone
Igneous rocks are formed from the solidification of magma or lava. An example is granite, known for its durability and resistance to weathering, making it ideal for parts of...