Abstract:
Background Diastolic pulmonary gradient (DPG) was proposed as a better marker of pulmonary vascular remodeling compared with pulmonary vascular resistance (PVR) and transpulmonary gradient (TPG). The prognostic significance of DPG in patients requiring a left ventricular assist device (LVAD) remains unclear. We sought to investigate whether pre-LVAD DPG is a predictor of survival or right ventricular (RV) failure post-LVAD. Methods and Results We retrospectively reviewed 268 patients who underwent right heart catheterization before LVAD implantation from 2007 to 2017 and had pulmonary hypertension because of left heart disease. Patients were dichotomized using DPG ≥7 mm Hg, PVR ≥3 mm Hg, or TPG ≥12 mm Hg. The associations between these parameters and all-cause mortality or RV failure post LVAD were assessed with Cox proportional hazards regression and Kaplan-Meier analyses. After a mean follow-up time of 35 months, elevated DPG was associated with increased risk of RV failure (hazard ratio [HR]: 3.30; P=0.004, for DPG ≥7 versus DPG <7), whereas elevated PVR (HR 1.85, P=0.13 for PVR ≥3 versus PVR <3) or TPG (HR 1.47, P=0.35, for TPG ≥12 versus TPG <12) were not associated with the development of RV failure. Elevated DPG was not associated with mortality risk (HR 1.16, P=0.54, for DPG ≥7 versus DPG <7), whereas elevated PVR, but not TPG, was associated with higher mortality risk (HR 1.55; P=0.026, for PVR ≥3 versus PVR <3). Conclusions Among patients with pulmonary hypertension because of left heart disease requiring LVAD support, elevated DPG was associated with RV failure but not survival, while elevated PVR predicted mortality post LVAD implantation.
More Related Videos
08:49Use of Two Intracorporeal Ventricular Assist Devices As a Total Artificial Heart
Published on: May 11, 2018
07:02A Large Animal Model for Pulmonary Hypertension and Right Ventricular Failure: Left Pulmonary Artery Ligation and Progressive Main Pulmonary Artery Banding in Sheep
Published on: July 15, 2021
Related Concept Videos
ECG Interpretation of Arrhythmias II: Atrial, Junctional and Ventricular Arrhythmias
Treatment for Pulmonary Arterial Hypertension: Oxygen Therapy for Respiratory Failure
Oxygen therapy is vital in increasing and maintaining blood oxygen levels in PAH patients. As a result, it aids in reducing fatigue,...
What is an Electrochemical Gradient?
The chemical gradient relies on differences in the abundance of a substance on the outside versus the inside of a cell and flows from areas of high to low ion concentration. In contrast, the electrical gradient revolves around an...
Energy Line and Hydraulic Gradient Line
Pathophysiology of Heart Failure
Heart Failure I: Introduction