Related Experiment Video
Updated: Jan 20, 2026

Prevention of Heat Stress Adverse Effects in Rats by Bacillus subtilis Strain
Published on: July 11, 2016
Intradermal Testing With Radiocontrast Media to Prevent Recurrent Adverse Reactions
Sung-Ryeol Kim1,2, Kyung Hee Park1,2, Yoo Jin Hong3,4
1Department of Internal Medicine, Division of Allergy and Immunology, Yonsei University College of Medicine, 50 Yonsei-ro, Seodaemun-gu, 03722 Seoul, Korea.
Abstract:
OBJECTIVE. Adverse drug reactions (ADRs) to radiocontrast media are a significant social and economic burden and are difficult to predict. Because some ADRs to radiocontrast media may be immunologically induced, a skin test with diluted 1:10 radiocontrast media has been used to predict ADRs. However, using this test in clinical practice is difficult because of its low sensitivity. SUBJECTS AND METHODS. This study enrolled 36 patients with a history of immediate ADR to radiocontrast media who visited the Allergy and Asthma Clinic of Severance Hospital from 2017 to 2018. Patients underwent intradermal testing (IDT) with five types of diluted (1:10) and undiluted radiocontrast media (iohexol, iobitridol, iopamidol, iopromide, and iodixanol). The IDT result was regarded as positive if at least one radiocontrast medium elicited a positive reaction. Positivity of IDT and sensitivity to the culprit radiocontrast medium were calculated and compared. For subsequent CT examinations with a radiocontrast medium, the contrast agent eliciting a negative skin reaction in IDT was selected, excluding the previous culprit radiocontrast medium. RESULTS. IDT positivity and sensitivity for the culprit radiocontrast medium at 1:10 dilution were 47.2% and 47.2%, respectively, whereas the positivity and sensitivity for the undiluted radiocontrast medium were 86.1% and 75.0%, respectively. The positivity and sensitivity were higher with frequent radiocontrast medium use or with severe reaction. Of 22 patients who underwent another CT examination with the contrast medium selected on the basis of IDT results, 21 (95.5%) did not experience an ADR. CONCLUSION. IDT to prevent ADR should be performed with undiluted radiocontrast medium. Selecting an alternative radiocontrast agent on the basis of IDT results can be clinically useful to prevent recurrent ADRs to radiocontrast media.
Related Concept Videos
Cancer Prevention
Some...
Local Anesthetics: Adverse Effects
Once absorbed into the systemic circulation, local anesthetics can affect the organs that depend on the functioning of sodium...
Skeletal Muscle Relaxants: Adverse Effects
Unlike...
Insulin: Dosing Regimen and Adverse Effects
The basal dose constitutes about 40%-50% of the total daily dose, with the rest as premeal insulin. The mealtime insulin dose should mirror...
Prevention of Further Absorption of Poison
Preventive Healthcare Services

