Relay: A Peer-Delivered Emergency Department-Based Response to Nonfatal Opioid Overdose

Alice E Welch1, Angela Jeffers1, Bennett Allen1

  • 1The authors are with the Bureau of Alcohol and Drug Use Prevention, Care, and Treatment, Division of Mental Hygiene, New York City Department of Health and Mental Hygiene, Queens, NY.

Related Concept Videos

Opioid Analgesics: Synthetic and Semisynthetic Opioids01:15

Opioid Analgesics: Synthetic and Semisynthetic Opioids

Synthetic and semisynthetic opioids are pivotal in pain management and tackling opioid addiction. Semisynthetic opioids, including morphinans (morphine derivatives), oxycodone, oxymorphone, hydrocodone, and hydromorphone, have improved pharmacokinetic profiles compared to morphine. Additionally, heroin and 6-MAM (6-Monoacetylmorphine) show better CNS penetration than morphine due to heightened lipid solubility. Hydromorphone, a potent opioid, undergoes hepatic metabolism to form the active...
948
Applications of GIS: Disaster Management and Emergency Response01:29

Applications of GIS: Disaster Management and Emergency Response

Geographic Information System (GIS) technology is essential for risk identification, action prioritization, and resource optimization in critical situations like flooding and earthquakes. By integrating spatial and demographic data, GIS provides a comprehensive framework for emergency response.GIS integrates data layers, like rainfall intensity, topography, elevation profiles, and river levels, to model high-risk flood zones. These layers assess areas susceptible to flooding based on their...
480
Directional Relays01:25

Directional Relays

Directional relays, essential for managing unidirectional fault currents, enhance the safety and efficiency of power systems. On power lines equipped with directional relays, faults downstream (to the right) of the current transformer typically cause the fault current to lag the bus voltage by approximately 90 degrees, known as the forward direction. In contrast, upstream (left-side) faults may result in the fault current leading the bus voltage by nearly 90 degrees, termed the reverse...
583
Overcurrent Relays01:26

Overcurrent Relays

Overcurrent relays, crucial for circuit protection, are connected to the secondary current of a current transformer. There are two primary types of overcurrent relays: instantaneous and time-delay.
Instantaneous overcurrent relays activate immediately when the input current exceeds a predetermined value, known as the pickup current, instantly energizing the circuit breaker trip coil. This rapid response is vital for addressing severe faults quickly.
Time-delay overcurrent relays, on the other...
498
Differential Relays01:20

Differential Relays

Differential relays are used to protect generators, buses, and transformers by comparing electrical quantities at different points. When a fault occurs, the difference in current between the two points triggers the relay to operate, opening the circuit breaker. Under normal conditions, the current entering (i1) and leaving (i2) a generator are equal. When a fault occurs, however, these currents become unequal, and the difference current flows in the relay operating coil, causing the relay to...
742
Line Protection with Impedance Relays01:27

Line Protection with Impedance Relays

Coordinating time-delay overcurrent relays in complex radial systems and directional overcurrent relays in multi-source transmission loops can be challenging. Impedance relays address these issues by responding to the voltage-to-current ratio, specifically measuring the apparent impedance of a line. These relays become more sensitive during faults as current increases and voltage decreases, thereby reducing the apparent impedance.
Under normal conditions, low load currents keep the measured...
441