Related Experiment Video
Updated: Jan 20, 2026

Single-Digit Nanometer Electron-Beam Lithography with an Aberration-Corrected Scanning Transmission Electron Microscope
Published on: September 14, 2018
Monte Carlo calculation of beam quality correction factors in proton beams using PENH
1KU Leuven, Department of Oncology, Laboratory of Experimental Radiotherapy, Leuven, Belgium. Hospital Clínic de Barcelona, Department of Radiation Oncology, Barcelona, Spain. Author to whom any correspondence should be addressed.
Abstract:
This work calculates beam quality correction factors ([Formula: see text]) in both modulated and unmodulated proton beams using the Monte Carlo (MC) code [Formula: see text]. The latest ICRU 90 recommendations on key data for ionizing-radiation dosimetry were adopted to calculate the electronic stopping powers and to select the mean energy to create an ion pair in dry air ([Formula: see text]). For modulated proton beams, [Formula: see text] factors were calculated in the middle of a spread-out Bragg peak, while for monoenergetic proton beams they were calculated at the entrance region. Fifteen ionization chambers were simulated. The [Formula: see text] factors calculated in this work were found to agree within 0.8% or better with the experimental data reported in the literature. For some ionization chambers, the simulation of proton nuclear interactions were found to have an effect on the [Formula: see text] factors of up to 1%; while for some others, perturbation factors were found to differ from unity by more than 1%. In addition, the combined standard uncertainty in the MC calculated [Formula: see text] factors in proton beams was estimated to be of the order of 1%. Thus, the results of this work seem to indicate that: (i) the simulation of proton nuclear interactions should be included in the MC calculation of [Formula: see text] factors in proton beams, (ii) perturbation factors in proton beams should not be neglected, and (iii) the detailed MC simulation of ionization chambers allows for an accurate and precise calculation of [Formula: see text] factors in clinical proton beams.
Related Concept Videos
Beams
Based on geometry, beams can be straight, tapered, or curved. Straight beams are the most common type and have a constant cross-section throughout their length. Tapered beams, on the other hand, have a varying cross-section along...
Deflection of a Beam
Singularity functions, described in an earlier lesson, are powerful mathematical tools that represent discontinuities within a function commonly encountered in structural loading...
Prismatic Beams: Problem Solving
The design begins with analyzing the beam as a free body to identify moments and force balances, thereby determining support reactions. Next, the...
Principal Stresses in a Beam
Analyzing principal stresses is crucial, especially in...
Beams with Symmetric Loadings
The M/EI...
Power Factor Correction

