Related Experiment Video
Updated: Jan 20, 2026

Preparation and Friction Force Microscopy Measurements of Immiscible, Opposing Polymer Brushes
Published on: December 24, 2014
Polymer brush based fluorescent immunosensor for direct monitoring of interleukin-1β in rat blood
Fei Deng1, Yi Li1, Md Jakir Hossain2
1Graduate School of Biomedical Engineering, ARC Centre of Excellence in Nanoscale Biophotonics, Faculty of Engineering, UNSW Sydney, NSW 2052, Australia. guozhen.liu@unsw.edu.au and Australian Centre for NanoMedicine, UNSW Sydney, NSW 2052, Australia.
A sandwich immunosensor was successfully developed for monitoring of interleukin-1β (IL-1β) in rat whole blood. The substrate stainless steel (SS) was first coated with a polydopamine layer and subsequently grafted with poly(ethylene glycol) methacrylate brushes, onto which a sandwich immunosensor was modified for detection of IL-1β. The device has been successfully applied for monitoring of IL-1β with a limit of detection of 4.7 pg mL-1, and a linear detection range of 12.5-200 pg mL-1. Good specificity and selectivity for monitoring of IL-1β in rat macrophage secretion were achieved. Furthermore, this device was validated by detection of IL-1β in rat whole blood samples with greater concentrations observed in obese rats compared to control, and strong positive correlation between concentrations of IL-1β and blood glucose. These results suggest this device is feasible for direct detection of target analytes in biological samples.
A sandwich immunosensor was successfully developed for monitoring of interleukin-1β (IL-1β) in rat whole blood. The substrate stainless steel (SS) was first coated with a polydopamine layer and subsequently grafted with poly(ethylene glycol) methacrylate brushes, onto which a sandwich immunosensor was modified for detection of IL-1β. The device has been successfully applied for monitoring of IL-1β with a limit of detection of 4.7 pg mL-1, and a linear detection range of 12.5-200 pg mL-1. Good specificity and selectivity for monitoring of IL-1β in rat macrophage secretion were achieved. Furthermore, this device was validated by detection of IL-1β in rat whole blood samples with greater concentrations observed in obese rats compared to control, and strong positive correlation between concentrations of IL-1β and blood glucose. These results suggest this device is feasible for direct detection of target analytes in biological samples.
More Related Videos
Related Concept Videos
Polymers
Polymers
Errors occurring during blood pressure monitoring
Several factors...
Crossed Aldol Reaction Using Strong Bases: Directed Aldol Reaction
Directing Effect of Substituents: meta-Directing Groups
Polymer Classification: Architecture

