Related Experiment Video
Updated: Jan 20, 2026

Quantitative 31P NMR Analysis of Lignins and Tannins
Published on: August 2, 2021
Quantification of surface functional groups on silica nanoparticles: comparison of thermogravimetric analysis and
Filip Kunc1, Vinod Balhara1, Ying Sun1
1National Research Council Canada, Ottawa, Ontario K1A 0R6, Canada. linda.johnston@nrc-cnrc.gc.ca.
Abstract:
Thermogravimetric analysis (TGA) coupled with evolved gas analysis-FT-IR has been examined as a potential method to study the functional group content for surface modified silica nanoparticles. A comparison with a quantitative solution NMR method based on analysis of groups released after dissolution of the silica matrix is used to provide benchmark data for comparison and to assess the utility and limitations of TGA. This study focused primarily on commercially available silicas and tested whether it was possible to use a correction based on bare silica to account for the significant mass loss that occurs due to condensation of surface hydroxyl groups and loss of matrix-entrapped components at temperatures above ∼200 °C. Although this approach has been used successfully in the literature for in-house prepared samples, it was problematic for commercial silicas prepared by the Stöber method. For these materials the agreement between estimates from qNMR and TGA mass loss was poor in many cases. However much better agreement was observed for samples for which the mass loss above 200 °C is relatively low, such as non-porous silica, or samples for which the mass fraction of functional group is large (e.g., high molecule weight groups or multilayers). FT-IR was useful in identifying the likely structure of the components lost from the surface at various temperatures and in some cases provided evidence of contaminants in the sample. Nevertheless, in other cases correlation of thermograms and FT-IR with NMR data was necessary, particularly for samples where multi-step modification of the silica surface results in incomplete functionalization that gives a mixture of products. Overall the results indicate that TGA provides reliable results for silicas of low porosity or those for which the functional group accounts for a significant fraction of the total sample mass. It is also suitable as a supplementary or screening technique to indicate the presence of coatings or covalent surface modification, prior to applying other techniques or for routine analyses where sensitivity is not critical.
Related Concept Videos
Quantitative Analysis
In quantitative analysis, two key measurements are made: the sample quantity and a property proportional to the amount of the analyte (the substance being analyzed). This forms the basis of the...
The Sense of Self: Reflected Self-Appraisal and Social Comparison
¹³C NMR: ¹H–¹³C Decoupling
A broadband decoupling technique is used to simplify these complex, sometimes overlapping, signals. Broadband decoupling relies on a...
Multiple Comparison Tests
It would be easy to compare two samples using a significance alpha level of 0.05. In other words, there is only one sample pair to be compared. However, it would be difficult to identify a significantly different sample if the number...
¹H NMR of Conformationally Flexible Molecules: Variable-Temperature NMR
Silica Gel Column Chromatography: Overview
Polar components tend to bind strongly to the silica gel, causing them to move slowly through the column. In contrast, nonpolar compounds...

